Author:
Zheng Shijun,Liang Ting,Hong Yinpin,Li Ying,Xiong Jijun
Abstract
Purpose
– The paper aims to highlight a wireless pressure-sensitive micro-device with high pressure sensitivity and accuracy. It is based on the partially stabilized Zirconia (PSZ) ceramic material which is capable of excellent elasticity and robustness.
Design/methodology/approach
– The paper begins with a general introduction to the wireless interrogating method and then the fabrication processes of the device using high temperature co-fired ceramic (HTCC) technology are described in detail.
Findings
– A passive wireless micro-device made from a novel material-PSZ ceramic on pressure monitoring is fabricated and tested and the authors proved that the device possesses an advantages over some proposed wireless sensors on interrogating distance. The pressure sensitivity of the device is 336 kHz/bar at readout distance 2.5 cm and that is an excellent property.
Originality/value
– The paper shows a new design scheme for wireless pressure measurement. The future application of the wireless device indicates the problem on external packaging and wire connection could be avoided. The allowable interrogation distance between the device and readout circuit reaches 2.5 cm which is mentioned for the first time so far. The distance is long enough to insert a thermal insulation material which can protect the vulnerable readout circuit from harsh environment, so the research finding is meaningful for the modern measurement technology.
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering
Reference20 articles.
1. Birol, H.
,
Maeder, T.
and
Ryser, P.
(2006), “Processing of graphite-based sacrificial layer for micro-fabrication of low temperature co-fired ceramic (LTCC)”, Sensors and Actuators A: Physical, Vol. 130/131, pp. 560-567.
2. Blasquez, G.
,
Pons, P.
and
Boukabache, A.
(1989), “Capabilities and limits of silicon pressure sensors”, Sensor and Actuators A: Physical, Vol. 17, pp. 387-403.
3. Cheong, K.Y.
(2007), “Silicon carbide (SiC)-based sensors for harsh environment applications”, available at: http://dspace.unimap.edu.my/dspace/handle/123456789/13821.
4. Cullinane, W.
and
Strange, R.
(1999), “Gas turbine engine validation instrumentation: measurements, sensors, and needs”, SPIE Conference on Harsh Environment Sensors, Vol. 3852, pp. 2-13.
5. Fonseca, M.
(2007), “Polymer/ceramic wireless MEMS pressure sensors for harsh environments: high temperature and biomedical applications”, available at: http://smartech.gatech.edu/xmlui/handle/1853/19789.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献