Author:
Abdulsalam Mohammed I.,Presuel-Moreno Francisco
Abstract
Purpose
The purpose of this paper is to study the susceptibility of these three commonly used corrosion resistance fasteners in seawater. For a more practical scenario, a local Atlantic coastal seawater as received was used.
Design/methodology/approach
Carbon fiber reinforced polymer (CFRP) was fabricated with T700 carbon fiber (Toray Inc.) and VE8084 vinyl ester resin (Ashland) to make a unidirectional composite panel of thickness 1.8 mm. A conductive paint was applied to one of the sample edges that was perpendicular to the fiber direction, providing an electrical contact with carbon fibers to connect a copper wire. This external electric connection was used for potential measurements of both the open circuit potential (OCP) of the CFRP sample, and the mixed potential of the fastened set: consisting of the CFRP and the metallic fastener fastened to it. Three common fastener alloys were selected: 316SS, Monel and Titanium. For this purpose, a high impedance voltmeter was used in conjunction with a saturated calomel reference electrode. Measurements were taken daily. For longer time measurements, a four-channel high impedance analog data logger was used with 30 min sampling rate.
Findings
For both 316SS and Monel fastened sets, crevice corrosion occurred inside the occluded regions of the set, when immersed in coastal seawater. The attack was more severe for 316 stainless steel set. An isolated island attack of faceted surfaces morphology was seen for 316SS set. While, a circular ring of preferential grain boundary attack appeared for Monel set, indicating an IR (voltage) drop mechanism is more likely operating. Titanium-fastened sets showed high resistance to crevice corrosion when simmered in seawater. However, for long-time exposure, the sets became more susceptible to crevice corrosion attack supported by CFRP attachment (oxygen reduction reaction taking place at the carbon fibers).
Originality/value
Evidently, titanium, stainless steels and Monel are good candidates for galvanic corrosion resistance. However, their susceptibility to crevice corrosion when coupled with CFRP is a new challenging topic that needs further investigation. This is very important today because the vast application witnessed for CFRP material. This work involves developing an original methodology for this kind of investigation and was done at advanced laboratories of SeaTech at Florida Atlantic University by the Atlantic coastline.
Subject
General Materials Science,General Chemical Engineering
Reference26 articles.
1. Crevice corrosion of titanium in high temperature-concentrated chloride environments;Journal of Materials Engineering and Performance,2007
2. Behaviour of crevice corrosion in iron;Corrosion Science,2005
3. Effect of the applied potential on the potential and current distributions within crevices in pure nickel;Corrosion Science,1999
4. The effect of crevice‐opening dimension on the stability of crevice corrosion for nickel in sulfuric acid;Journal of the Electrochemical Society,1998
5. The effect of a seawater environment on the galvanic corrosion behavior of graphite/epoxy composites coupled to metals,1992
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献