Thermal comfort prediction of air-conditioned and passively cooled engineering testing centres in a higher educational institution using CFD

Author:

Kwong Qi Jie,Yang Jim Yexin,Ling Oliver Hoon Leh,Edwards Rodger,Abdullah Jamalunlaili

Abstract

PurposeThe purpose of this paper is to analyse the thermal environment of two engineering testing centres cooled via different means using computational fluid dynamics (CFD), focussing on the indoor temperature and air movement. This computational technique has been used in the analysis of thermal environment in buildings where the profiles of thermal comfort parameters, such as air temperature and velocity, are studied.Design/methodology/approachA pilot survey was conducted at two engineering testing centres – a passively cooled workshop and an air-conditioned laboratory. Electronic sensors were used in addition to building design documentation to collect the required information for the CFD model–based prediction of air temperature and velocity distribution patterns for the laboratory and workshop. In the models, both laboratory and workshop were presumed to be fully occupied. The predictions were then compared to empirical data that were obtained from field measurements. Operative temperature and predicted mean vote (PMV)–predicted percentage dissatisfied (PPD) indices were calculated in each case in order to predict thermal comfort levels.FindingsThe simulated results indicated that the mean air temperatures of 21.5°C and 32.4°C in the laboratory and workshop, respectively, were in excess of the recommended thermal comfort ranges specified in MS1525, a local energy efficiency guideline for non-residential buildings. However, air velocities above 0.3 m/s were predicted in the two testing facilities, which would be acceptable to most occupants. Based on the calculated PMV derived from the CFD predictions, the thermal sensation of users of the air-conditioned laboratory was predicted as −1.7 where a “slightly cool” thermal experience would prevail, but machinery operators in the workshop would find their thermal environment too warm with an overall sensation score of 2.4. A comparison of the simulated and empirical results showed that the air temperatures were in good agreement with a percentage of difference below 2%. However, the level of correlation was not replicated for the air velocity results, owing to uncertainties in the selected boundary conditions, which was due to limitations in the measuring instrumentation used.Research limitations/implicationsDue to the varying designs, the simulated results of this study are only applicable to laboratory and workshop facilities located in the tropics.Practical implicationsThe results of this study will enable building services and air-conditioning engineers, especially those who are in charge of the air-conditioning and mechanical ventilation (ACMV) system design and maintenance to have a better understanding of the thermal environment and comfort conditions in the testing facilities, leading to a more effective technical and managerial planning for an optimised thermal comfort management. The method of this work can be extended to the development of CFD models for other testing facilities in educational institutions.Social implicationsThe findings of this work are particularly useful for both industry and academia as the indoor environment of real engineering testing facilities were simulated and analysed. Students and staff in the higher educational institutions would benefit from the improved thermal comfort conditions in these facilities.Originality/valueFor the time being, CFD studies have been carried out to evaluate thermal comfort conditions in various building spaces. However, the information of thermal comfort in the engineering testing centres, of particular those in the hot–humid region are scantily available. The outcomes of this simulation work showed the usefulness of CFD in assisting the management of such facilities not only in the design of efficient ACMV systems but also in enhancing indoor thermal comfort.

Publisher

Emerald

Subject

Management, Monitoring, Policy and Law,Urban Studies,Building and Construction,Renewable Energy, Sustainability and the Environment,Civil and Structural Engineering,Human Factors and Ergonomics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3