Numerical evaluation of pedestrian-level wind and indoor thermal comfort of a historical monument, Muğla, Turkey

Author:

Gençer FundaORCID,Karadağ İlkerORCID

Abstract

PurposeThe study aims to analyze both thermal and wind comfort conditions of a historical mosque's interior and outdoor spaces for the planning of further conservation decisions.Design/methodology/approachThe method is composed of two steps. First, thermal comfort analyses are conducted via Design-Builder Software. The predicted mean vote (PMV) and predicted percentage of dissatisfied indices were calculated and evaluated using the ASHRAE 55–2010 standard. Thermal comfort conditions are analyzed with the proposed three operations. Second, wind comfort analyses are conducted via computational fluid dynamics (CFD) software. Outdoor thermal comfort conditions are predicted by air temperature, mean radiant temperature, wind speed and relative humidity.FindingsThe (PMV) in the harim was calculated as −1.83 (cool) which corresponds to a predicted percentage of dissatisfaction (PPD) equal to 68.54%. Thermal comfort was provided by daytime and continuous operations; however, intermittent operations did not provide thermal comfort. The wind velocities around the mosque are well below the 5 m/s limit value for standing defined by NEN 8100 wind nuisance standard. Moreover, the limit value of 2.5 m/s for sitting was also satisfied with more than 80% of the semi-enclosed area around the entrance of the mosque. Last comer's hall remains in a slight cold stress range, the rest of the areas have no thermal stress.Originality/valueThis two-stage study creates a base for further improvements to provide comfort conditions in a historical building without interfering with its original features.

Publisher

Emerald

Subject

Urban Studies,Geography, Planning and Development,Architecture

Reference47 articles.

1. Investigation of indoor air quality and thermal comfort condition in airport terminal buildings;Aircraft Engineering and Aerospace Technology,2021

2. Thermal comfort in air-conditioned mosques in the dry desert climate;Building and Environment,2010

3. The influence of angular configuration of two buildings on the local wind climate;Journal of Wind Engineering and Industrial Aerodynamics,2016

4. Thermal comfort around the holy mosques;Arabian Journal for Science and Engineering,2017

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3