Abstract
AbstractObjective:This study aimed to compare the functional and anatomical outcomes of ossiculoplasty using an autograft incus or a titanium partial ossicular replacement prosthesis for reconstructing Austin type A ossicular defects.Methods:Patients with Austin A ossicular defects were randomly divided into two groups: one group underwent ossiculoplasty with an autologous incus (the autologous incus group) and the other underwent ossiculoplasty with a titanium partial ossicular replacement prosthesis (the titanium prosthesis group). Otoscopic examination and audiological assessment was done pre-operatively and at 3, 6 and 12 months post-operatively.Results:A post-operative average air–bone gap closure of less than 20 dB was seen in 13 patients (65 per cent) in the autologous incus group and 7 (35 per cent) in the titanium prosthesis group. There were fewer post-operative complications in the autologous incus group (20 per cent) than in the titanium prosthesis group (45 per cent).Conclusion:Hearing outcomes and graft take up after ossiculoplasty were significantly better when an autologous incus rather than a titanium partial ossicular replacement prosthesis was used to reconstruct Austin type A ossicular defects. The major disadvantages of the titanium prosthesis were unpredictable results and more post-operative complications.