Comparison of skin doses of treated and contralateral breasts during whole breast radiotherapy for different treatment techniques using optically stimulated luminescent dosimeters

Author:

Gopalakrishnan ZheniaORCID,Nair RaghuRam K.ORCID,Raghukumar P.ORCID,Bhasi SajuORCID,Menon Sharika V.ORCID

Abstract

AbstractPurpose:To measure and compare the skin doses received by treated left breast and contralateral breast (CB) during whole breast radiotherapy using five treatment techniques in an indigenously prepared wax breast phantom.Materials and methods:Computed tomography (CT) images of the breast phantom were used for treatment planning and comparison of skin dose calculated from treatment planning system (TPS) with measured dose. Planning target volume (PTV) and the CB were drawn arbitrarily on the CT images acquired for the breast phantom with 10 numbers of calibrated optically stimulated luminescent dosimeters (OSLDs) fixed on the surface of both breasts. The TPS calculated surface doses of PTV breast and CB for five treatment planning techniques, viz., conventional wedge (CW), irregular surface compensator-based (ISC), field-in-field (FiF), intensity-modulated radiotherapy (IMRT) and rapid arc (RA) techniques were obtained for comparison. The plans were executed in Clinac iX Linear Accelerator with the OSLDs fixed at the same locations on the phantom as in simulation. The TPS calculated mean dose at the surface of the treated left breast and CB was noted for the 10 OSLDs from dose-volume histogram (DVH) and compared with the measured dose. Also, the mean chamber dose at the centre of the left breast was noted from the DVH for comparing with ion chamber measured dose.Results:With reference to the results, it is seen that the dose to the CB is lowest in ISC technique and FiF technique and greatest in IMRT technique. The CW technique also delivered a dose comparable to IMRT to the CB of the phantom. The dose to the surface of PTV breast was highest and comparable in CW plans and FiF plans (68% and 67%) and lowest in IMRT and RA plans (50% each).Findings:Analysis of the results shows that the FiF and ISC techniques are preferred while planning breast radiotherapy due to the reduced dose to the CB.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Evaluation of Surface Dose for Intensity Modulated Radiotherapy of Head and Neck Cancer Using Thermoluminescent Dosimeters;Gazi University Journal of Science Part A: Engineering and Innovation;2022-06-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3