Assessing a new coarctation repair simulator based on real patient’s anatomy

Author:

Kleszcz JacekORCID,Sobieraj Michał,Nałęcz Tomasz,Myers Patrick O.,Wojtalik Michał,Mrówczyński Wojciech

Abstract

AbstractObjectives:To perform the preliminary tests of coarctation of aorta repair trainer, evaluate the surgical properties of the simulation and to assess and enhance residents’ skills.Methods:Single patient’s angio-CT anatomy data were converted into magnified 3D-printed model of aortic coarctation with hypoplastic aortic arch, serving for creation of a mould used during wax copies casting. Wax cores were painted with six layers of elastic silicone and melted, yielding phantoms that were consecutively fixed in a mounting with and without a thoracic wall. Simulation included: proximal and distal aortic arch clamping, incision of its lesser curvature, extended end-to-end anastomosis with 7-0 suture. A head-mounted camera video recording enabled anastomosis time and mean one suture bite time evaluation. Leakage assessment was done by a water test.Results:Two residents performed nine simulations each. Last four runs were performed with thoracic wall attached. All phantoms performed well, enabling tissue-like handling and cutting, excellent suture retention, and satisfactory elasticity. Median anastomosis times were 22′33″ and 24′47″ for phantoms without and with thoracic wall (p = not significant (NS)). Median times needed to pass suture through one side of anastomosis and regrasp needle were, respectively, 9″ and 13″ (p < 0.001). Median total number of leakages per phantom equalled 2 for both difficulty levels. There were no significant inter-resident differences in all assessed parameters.Conclusions:This medium-fidelity aortic coarctation repair trainer showed its feasibility in replication of major critical steps of the real operation. Objective surgical efficiency parameters could be obtained from each simulation and compared between trainees and at different adjustable difficulty levels.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3