Choice of appropriate beam model and gantry rotational angle for low-dose gradient-based craniospinal irradiation using volumetric-modulated arc therapy

Author:

Sarkar Biplab,Pradhan Anirudh

Abstract

AbstractObjectivesWe aimed to assess the impact of advanced multileaf collimator (MLC) models and flattening filter-free (3F) beam in volumetric-modulated arc therapy (VMAT)-based craniospinal irradiation (CSI).MethodsCT scans of five medulloblastoma patients who previously received CSI at our hospital were used for the present study. Patients were planned for a prescription dose of 35 Gy to craniospinal axis. A three-dimensional conformal radiotherapy (3DCRT) plan and a VMAT plan using 1 cm MLC leaf width were generated as the gold standard (reference arm). Test VMAT plans were generated using Agility MLC model (MLC leaf width 5 mm) for various combinations of flattened beam (F) and 3F beam for treating the brain and spine planning target volume (PTV). Organs at risks (OARs) were analysed for dose 5, 50, 75 and 90% volumes, mean dose and maximum dose.ResultsAll 3DCRT plans and VMAT plans were aimed to cover 95% of PTV by at least 95% prescription dose. VMAT demonstrated lesser dose spillage than 3DCRT to body volume minus PTV (NTID: non tumor integral dose) for a dose threshold above 7·5 Gy. For the low-dose range (1–7 Gy), variation between the dose coverage between all VMAT plans (for either spine or brain PTV) was <1%. Intra-VMAT plan dose variation for all OAR’s for all tested parameters was <1 Gy. Average monitor unit (MU) difference among different VMAT plans ranged between 1·52 and 2·13 when normalised to 3DCRT MU. For VMAT plans, flat beam with 1 cm MLC showed the highest MU, whereas Agility MLC with 3F beam had the least MU values for intra-VMAT plans. No statistical significance variation (p) was observed in between reference arm and test arm plans except for mean dose and V107% for PTV spine. When compared between reference arm 3DCRT and test arm VMAT plans. For OAR’s, no statistical difference was observed between reference and test arm VMAT plans.ConclusionsReference arm plans and test arm plans exhibit no statistically significant difference. However, as compared with 3DCRT, VMAT plans are more conformal and produce lesser dose to OAR at the cost of higher delivered MU. 3F beams or finer width MLC’s (width <5 mm) have no advantage over the conventional 1 cm MLC and flat beam except that 3F beams have a shorter beam delivery time. This study demonstrate a significantly lesser spillage dose to NTID/body that of the reported literature, which is attributed to limited rotational arc length used for VMAT plans.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3