Experimental measurements and Monte Carlo modelling of the XSTRAHL 150 superficial X-ray therapy unit

Author:

Al-Ghorabie Fayez H. H.

Abstract

AbstractBackgroundSuperficial X-ray therapy units are used for the treatment of certain types of skin cancer and some severe dermatological conditions. The performance assessment and beam characteristics of the superficial unit are very important to ensure accurate dose delivery during patient treatment. Both experimental measurements and Monte Carlo calculations can be used for this purpose.PurposeThis study aims to investigate whether it is possible to reproduce experimentally measured data for the XSTRAHL 150 superficial X-ray unit with simulations using the BEAMnrc Monte Carlo code.Materials and MethodsThe experimental procedure applied in this study included the following: experimental measurements of different X-ray spectra, half-value layers, percentage depth dose and beam profiles. Monte Carlo modelling of the XSTRAHL 150 unit was performed with the BEAMnrc code. The validity of the model was checked by comparing the theoretical calculations with experimental measurements.ResultsThere was good agreement (∼1%) between experimentally measured and simulated X-ray spectra. Results of half-value layers obtained from simulated and measured spectra showed that there was a maximum of 3·6% difference between BEAMnrc and measurements and a minimum of 2·3%. In addition, simulated percentage depth dose and profile curves have been compared against experimental measurements and show good agreement (within 2% for the depth dose curves and 3–5% for beam profile curves, depending on the applicator size).ConclusionThe results of this study provide information about particles’ interaction in different kilovoltage and filter combinations. This information is useful for X-ray tube design and development of new target/filter combinations to improve beam quality in superficial X-ray radiotherapy. The data presented here may provide a base for comparison and a reference for other or potential new users of the XSTRAHL 150 X-ray unit.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

Reference27 articles.

1. Performance assessment of the Gulmay D3300 kilovoltage X-ray therapy unit

2. Modification and benchmarking ofMCNPfor low-energy tungsten spectra

3. Matzke M . Unfolding of pulse height spectra: the HEPRO program system. Report No.: PTB-N-19. Braunschweig (Germany): Physikalisch-Technische Bundesanstalt, 1994.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3