Determination of computed tomography number of high-density materials in 12-bit, 12-bit extended and 16-bit depth for dosimetric calculation in treatment planning system

Author:

Jayamani JayapramilaORCID,Osman Noor Diyana,Tajuddin Abdul Aziz,Salehi Zaker,Ali Mohd Hanafi,Abdul Aziz Mohd Zahri

Abstract

AbstractAimThe main aim was to examine the effect of bit depth on computed tomography (CT) number for high-density materials. Analysis of the CT number for high-density materials using 16-bit scanners will extend the CT scale that currently exists for 12-bit scanners and thus will be beneficial for use in CT–electron density (ED) curve in radiotherapy treatment planning system (TPS). Implementation of this extended CT scale will compensate for tissue heterogeneity during CT–ED conversion in treatment planning.Materials and methodsAn in-house built phantom with 10 different metal samples was scanned using 80, 100 and 120 kVp in two different CT scanners. A region of interest was set at the centre of the material and the mean CT numbers together with data deviation were determined. Dosimetry calculation was performed by applying a direct anterior beam on 12-bit, 12-bit extended and 16-bit.ResultsHigh-density materials (>4·34 g cm−3) in 16-bit depth provide disparities up to 44% compared to Siemens’ 12-bit extended. Influence of tube voltage showed a significant difference (p<0·05) in both bit depth and CT number of the gold and amalgam saturated in 16-bit depth. A 120 kVp energy illustrated a low variation on CT number for different scanners, but dosimetry calculation showed significant disparities at the metal interface in 12-bit, 12-bit extended and 16-bit.FindingsHigh-density materials require 16-bit scanners to obtain CT number to be implemented in treatment planning in radiotherapy. This also suggests that proper tube voltage together with correct CT–ED resulted in accurate TPS algorithm calculation.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3