Importance of Carbon Contamination in High-Resolution (FEG) EPMA of Silicate Minerals

Author:

Buse Ben,Kearns Stuart

Abstract

AbstractThe effect of carbon contamination on the analysis of carbon-coated silicate minerals at 5 kV for X-ray energies 0.7–4 keV is examined. For individual spot analyses, carbon is found to deposit adjacent to the beam spot forming ring-shaped deposits with no impact on the analysis. Carbon contamination becomes important for closely spaced analyses such as multipoint transects, where each subsequent analysis overlaps the carbon ring of the previous analysis. X-ray intensity loss due to contamination is most severe for low-overvoltage elements such as Ca K consistent with carbon deposition effectively reducing beam energy. Rates of contamination are calculated and the use of a liquid nitrogen cold trap is shown to greatly reduce the amount of carbon deposited. A complimentary empirical correction is developed to correct for X-ray intensity loss from measured carbon, assuming the carbon is a film, and is compared with corrections derived from thin film calculations. PENELOPE electron probe microanalysis (PENEPMA) calculations confirm that asymmetry of the carbon deposition can be ignored for X-ray energies where intensity loss is predominantly through energy loss of beam electrons. Using a cold trap and/or an empirical correction high spatial resolution analysis (ca. 400 nm between points) is achievable with analytical errors of ca. 1–3%.

Publisher

Cambridge University Press (CUP)

Subject

Instrumentation

Reference26 articles.

1. Pinard P.T. , Demers H. , Gauvin R. & Richter S . (2013 b). High resolution carbon measurements in steel using FE-EPMA. EMAS 2013 Conference Abstract.

2. Quantitative electron probe microanalysis of ultralight elements (boron-oxygen)

3. Plasma Cleaning and Its Applications for Electron Microscopy

4. Bastin G.F. & Heijligers H.J.M. (1990 a). Quantitative Electron Probe Microanalysis of Carbon in Binary Carbides. Internal Report, Eindhoven University of Technology.

5. Low-Voltage Electron-Probe Microanalysis of Fe–Si Compounds Using Soft X-Rays

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献