Effect of Hydroxocobalamin on Surface Oximetry in Nonexposed Humans

Author:

Cashin Brian V.,Matlock Aaron G.,Kang Chris,Reynolds Penny S.,Wills Brandon K.

Abstract

AbstractIntroductionThe newer cyanide antidote, hydroxocobalamin, due to its pigmentation, has been found to cause interferences in some laboratory assays. Co-oximetry may also be affected by hydroxocobalamin, leading to false elevations in hemoglobin concentration, methemoglobin, carboxyhemoglobin, and false decreases in oxyhemoglobin. The Masimo Radical-7 is a medical device that performs noninvasive oximetry and estimates hemoglobin (Hb) concentration and percent carboxyhemoglobin (COHb), methemoglobin (MetHb), and oxyhemoglobin saturation (O2Hb).Study ObjectivesThe study sought to determine the effect of hydroxocobalamin on noninvasive measurement of hemoglobin indices using the Masimo Radical-7 monitor.MethodsSeven asymptomatic volunteers who were unexposed to cyanide had baseline heart rate (HR), blood pressure (BP), and oximeter measurements recorded followed by an infusion of five grams of hydroxocobalamin over 15 minutes. The above parameters were subsequently recorded at: 5, 10, 15, 30 and 60 minutes post infusion. Data were analyzed by calculating the area under the curve (AUC) for each variable and comparing the results to expected values by pairedttests. Expected AUC values were calculated by extrapolating baseline values across the entire time period.ResultsThe mean differences from baseline values with 95% confidence intervals andttests of mean difference were: SBP: 11 mm Hg (95% CI, 0-22;P= .051); HR: -9 (95% CI, -15 to -3;P= .01); Hb: -0.1 (95% CI, -0.7 to 0.4;P= .57); O2Hb: 0 g/dL (95% CI, -1 to 1;P= .41); COHb: -1 (95% CI, -3 to 1;P= .25); MetHb: -0.2 (95% CI, -0.3 to 0;P= .03).DiscussionAfter infusion of hydroxocobalamin there was a significant elevation of systolic blood pressure and decrease in heart rate. There were no significant differences in Hb, O2Hb, and COHb. Although percent methemoglobin concentrations were statistically lower, the authors feel this difference is of trivial clinical significance.ConclusionThe administration of hydroxocobalamin does not significantly impact noninvasive oximetry.CashinB,MatlockA,KangC,ReynoldsP,WillsB.Effect of hydroxocobalamin on surface oximetry in nonexposed humans.Prehosp Disaster Med.2013;28(4):1-3.

Publisher

Cambridge University Press (CUP)

Subject

Emergency Nursing,Emergency Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3