Haemodynamic changes due to delayed sternal closure in newborns after surgery for congenital cardiac malformations

Author:

Vojtovič Pavel,Reich Oleg,Selko Marek,Tláskal Tomáš,Hostaša Jiří,Matějka Tomáš,Gebauer Roman,Gabriel Otakar,Chaloupecký Václav

Abstract

AbstractBackgroundDelayed sternal closure is used to prevent low cardiac output syndrome in selected newborns shortly after cardiac surgery for congenital cardiac defects. Sternal closure itself often causes haemodynamic and ventilatory instability that cannot be entirely assessed by standard monitoring means. Therefore, we used transpulmonary thermodilution technique for an exact evaluation of the haemodynamic changes.Patients and methodsBetween April, 2006, and December, 2008, 23 neonates aged from 1 to 30 days, with a median of 7 days, and weighing from 1.9 to 4.2 kilograms, with a median of 3.25 kilograms, were studied after biventricular corrections. Residual intracardiac shunts were excluded by echocardiography. Haemodynamic and ventilatory parameters, along with those obtained by the transpulmonary thermodilution technique, were recorded before and immediately after the sternal closure, and then at 0.5, 1, 2, 6, 12, 24, and 48 hours.ResultsChest closure caused significant decrease in systolic arterial pressure from 80.04 ± 11.48 to 69.48 ± 9.63 mmHg (p < 0.001), cardiac index from [median (25th/75th centile)] 2.640 (2.355/2.950) to 2.070 (1.860/2.420) l/min/m2 (p < 0.001), stroke volume index from 18.50 (16.00/20.00) to 14.00 (11.00/17.00) ml/m2 (p < 0.001), and dynamic lung compliance from 2.45 (2.31/3.00) to 2.30 (2.14/2.77) ml/cmH2O (p = 0.007). Stroke volume variation increased from 14.00 (9.25/16.75) to 18.00 (15.00/21.00) % (p < 0.001). The oxygenation index transitorily increased from 2.50 (2.14/3.15) to 3.36 (2.63/4.29) (p < 0.001). Serum lactate decreased from 1.40 (1.12/2.27) to 1.0 (0.8/1.3)mmol/l, p < 0.001 in coincidence with a haemodynamic stabilisation at a later time after chest closure. Cardiopulmonary instability caused by the sternal closure necessitated therapeutic intervention in 18 of 23 patients (78.3%).ConclusionDelayed sternal closure causes a significant transitory decrease in stroke volume, cardiac output and arterial blood pressure. Also lung compliance and blood oxygenation are temporarily significantly compromised.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3