Physiologic effects of delayed sternal closure following stage 1 palliation

Author:

Mills Kimberly I.,van den Bosch Sarah J.,Gauvreau Kimberlee,Allan Catherine K.,Thiagarajan Ravi R.,Hoganson David M.,Baird Christopher W.,Nathan Meena,DiNardo James A.,Kheir John N.

Abstract

AbstractBackgroundFollowing stage 1 palliation, delayed sternal closure may be used as a technique to enhance thoracic compliance but may also prolong the length of stay and increase the risk of infection.MethodsWe reviewed all neonates undergoing stage 1 palliation at our institution between 2010 and 2017 to describe the effects of delayed sternal closure.ResultsDuring the study period, 193 patients underwent stage 1 palliation, of whom 12 died before an attempt at sternal closure. Among the 25 patients who underwent primary sternal closure, 4 (16%) had sternal reopening within 24 hours. Among the 156 infants who underwent delayed sternal closure at 4 [3,6] days post-operatively, 11 (7.1%) had one or more failed attempts at sternal closure. Patients undergoing primary sternal closure had a shorter duration of mechanical ventilation and intensive care unit length of stay. Patients who failed delayed sternal closure had a longer aortic cross-clamp time (123±42 versus 99±35 minutes, p=0.029) and circulatory arrest time (39±28 versus 19±17 minutes, p=0.0009) than those who did not fail. Failure of delayed sternal closure was also closely associated with Technical Performance Score: 1.3% of patients with a score of 1 failed sternal closure compared with 18.9% of patients with a score of 3 (p=0.0028). Among the haemodynamic and ventilatory parameters studied, only superior caval vein saturation following sternal closure was different between patients who did and did not fail sternal closure (30±7 versus 42±10%, p=0.002). All patients who failed sternal closure did so within 24 hours owing to hypoxaemia, hypercarbia, or haemodynamic impairment.ConclusionWhen performed according to our current clinical practice, sternal closure causes transient and mild changes in haemodynamic and ventilatory parameters. Monitoring of SvO2following sternal closure may permit early identification of patients at risk for failure.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3