Simulation of photic effects after cataract surgery for off-axis light sources

Author:

Omidi PooriaORCID,Cayless Alan,Langenbucher Achim

Abstract

Photopsia is a phenomenon that sometimes disturbs patients after cataract surgery. To evaluate the impact of the edge design of intraocular lenses (IOL) on the location, shape and relative intensity of photic effects at the retina caused by photopsia in pseudophakic eyes, photopsia was simulated using ZEMAX software. The structural parameters of the pseudophakic eye model are based on the Liou-Brennan eye model parameters with a pupil diameter of 4.5 mm. The IOLs implanted in the eye model have a power of 21 diopter (D) with optical diameter of 6 mm and 7 mm. From the ray-tracing analysis, covering variations of incident ray angle of 50° to 90° from temporally, a photic image is detected at the fovea at specific ray angles of 77.5° (6 mm IOL) and 78.2° (7 mm IOL). This photic image disappears when a thin IOL with an edge thickness of 0 mm or a thick IOL with absorbing edges is replaced in the eye model. With an anti-reflective edge, this photic image remains, but with a fully reflecting edge it disappears at the critical angles and appears with different shapes at other angles. The intensity of this photic image can be reduced by changing the edge design to a frosted surface. Most of the photic patterns in IOLs are not observed with absorbing and thin edge designs. IOLs with anti-reflecting and fully reflecting edges generate disturbing photic effects at different angles on the fovea. IOLs with frosted edges reduce the contrast of the photic effects and make them less disturbing for patients.

Funder

Rolf M. Schwiete Stiftung

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference15 articles.

1. Undesired light images associated with ovoid intraocular lenses.;S Masket;Journal of Cataract & Refractive Surgery,1993

2. Dysphotopsia in phakic and pseudophakic patients: incidence and relation to intraocular lens type.;R Tester;Journal of Cataract & Refractive Surgery,2000

3. Positive and negative dysphotopsia in patients with acrylic intraocular lenses.;JA Davison;Journal of Cataract & Refractive Surgery,2000

4. Negative dysphotopsia associated with implantation Z9000 intraocular lens.;J Narváez;Journal of Cataract & Refractive Surgery,2005

5. Comparison of pseudophakic dysphotopsia with Akreos Adapt and SN60-AT intraocular lenses.;SW Radford;Journal of Cataract & Refractive Surgery,2007

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3