Intraorbital pressure–volume characteristics in a piglet model: In vivo pilot study

Author:

Hamarat YasinORCID,Bartusis Laimonas,Putnynaite Vilma,Zakelis Rolandas,Deimantavicius Mantas,Zigmantaite Vilma,Grigaleviciute Ramunė,Kucinskas Audrius,Kalvaitis Evaldas,Ragauskas Arminas

Abstract

Intracranial pressure measurement is frequently used for diagnosis in neurocritical care but cannot always accurately predict neurological deterioration. Intracranial compliance plays a significant role in maintaining cerebral blood flow, cerebral perfusion pressure, and intracranial pressure. This study’s objective was to investigate the feasibility of transferring external pressure into the eye orbit in a large-animal model while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures. The experimental system comprised a specifically designed pressure applicator that can be placed and tightly fastened onto the eye. A pressure chamber made from thin, elastic, non-allergenic film was attached to the lower part of the applicator and placed in contact with the eyelid and surrounding tissues of piglets’ eyeballs. External pressure was increased from 0 to 20 mmHg with steps of 1 mmHg, from 20 to 30 mmHg with steps of 2 mmHg, and from 30 to 50 mmHg with steps of 5 mmHg. An invasive pressure sensor was used to measure intraorbital pressure directly. An equation was derived from measured intraorbital and external pressures (intraorbital pressure = 0.82 × external pressure + 3.12) and demonstrated that external pressure can be linearly transferred to orbit tissues with a bias (systematic error) of 3.12 mmHg. This is close to the initial intraorbital pressure within the range of pressures tested. We determined the relationship between intraorbital compliance and externally applied pressure. Our findings indicate that intraorbital compliance can be controlled across a wide range of 1.55 to 0.15 ml/mmHg. We observed that external pressure transfer into the orbit can be achieved while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures.

Funder

European Social Fund

European Regional Development Fund

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3