Injection time related to intraocular pressure using a CO2 driven preloaded injector: An experimental laboratory study

Author:

Weindler Jan N.ORCID,Naujokaitis TadasORCID,Schickhardt Sonja K.,Khoramnia Ramin,Auffarth Gerd U.

Abstract

Purpose Experimental study to measure the intraocular lens (IOL) injection time and injection speed at different intraocular pressure (IOP) settings when using the AutonoMe® injector. Methods In this experimental study, following phacoemulsification in porcine cadaver eyes, a trocar was inserted at pars plana with a connected infusion and IOPs of 20, 50 and 80 mmHg were generated by altering the infusion height. Twelve CO2 gas-driven injectors were used to implant an IOL via a corneal incision of 2.2 mm. For each IOP setting, the duration of the IOL injection and the injection speed was measured by analyzing a video recording of the procedure. Results The mean ±SD injection time (seconds) was 4.47±0.50 at 20 mmHg, 4.98±0.55 at 50 mmHg and 5.47±0.20 at 80 mmHg. The mean ±SD injection speed (millimeters per seconds) was 1.36±0.15 at 20 mmHg, 1.22±0.14 at 50 mmHg and 1.10±0.04 at 80 mmHg. There was a significant (p<0.05) difference between the 20 and 80 mmHg groups in mean injection duration and injection speed. Conclusion The CO2 gas driven injector allows a safe IOL injection even at elevated IOP. Although the implantation time is slightly extended at higher IOPs, this does not seem to be clinically relevant. No IOL damage was observed at these pressure settings.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference20 articles.

1. Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial;B Chung;International journal of ophthalmology,2018

2. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery;JJ Jones;Clin Ophthalmol,2016

3. A 10 year retrospective survey of cataract surgery and endophthalmitis in a single eye unit: injectable lenses lower the incidence of endophthalmitis;E Mayer;The British Journal of Ophthalmology,2003

4. Identification of unknown intraocular material after cataract surgery: evaluation of a potential cause of toxic anterior segment syndrome;KC Mathys;J Cataract Refract Surg,2008

5. Toxic anterior segment syndrome after cataract surgery—Maine, 2006;MMWR Morb Mortal Wkly Rep,2007

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献