Measure by measure: Resting heart rate across the 24-hour cycle

Author:

Speed CathyORCID,Arneil Thomas,Harle Robert,Wilson Alex,Karthikesalingam Alan,McConnell MichaelORCID,Phillips JustinORCID

Abstract

Background Photoplethysmography (PPG) sensors, typically found in wrist-worn devices, can continuously monitor heart rate (HR) in large populations in real-world settings. Resting heart rate (RHR) is an important biomarker of morbidities and mortality, but no universally accepted definition nor measurement criteria exist. In this study, we provide a working definition of RHR and describe a method for accurate measurement of this biomarker, recorded using PPG derived from wristband measurement across the 24-hour cycle. Methods 433 healthy subjects wore a wrist device that measured activity and HR for up to 3 months. HR during inactivity was recorded and the duration of inactivity needed for HR to stabilise was ascertained. We identified the lowest HR during each 24-hour cycle (true RHR) and examined the time of day or night this occurred. The variation of HR during inactivity through the 24-hour cycle was also assessed. The sample was also subdivided according to daily activity levels for subset analysis. Findings Adequate data was obtained for 19,242 days and 18,520 nights. HR stabilised in most subjects after 4 minutes of inactivity. Mean (SD) RHR for the sample was 54.5 (8.0) bpm (day) and 50.5 (7.6) bpm (night). RHR values were highest in the least active group (lowest MET quartile). A circadian variation of HR during inactivity was confirmed, with the lowest values being between 0300 and 0700 hours for most subjects. Interpretation RHR measured using a PPG-based wrist-worn device is significantly lower at night than in the day, and a circadian rhythm of HR during inactivity was confirmed. Since RHR is such an important health metric, clarity on the definition and measurement methodology used is important. For most subjects, a minimum rest time of 4 minutes provides a reliable measurement of HR during inactivity and true RHR in a 24-hour cycle is best measured between 0300 and 0700 hours. Funding: This study was funded by Google.

Funder

Google

Publisher

Public Library of Science (PLoS)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3