Abstract
Monoclonal Antibodies (mAbs) are being used in the treatment of both malignant and non-malignant diseases and whilst highly effective, certain products have very short expiry times. Clinical deterioration and supply chain disruption can often lead to wastage and there is a need to reduce this by improving efficiency in logistics practices between manufacturing sites and administration locations. This study aimed to investigate the influence of drone flight on the stability of cancer medicines. Clinically expired, premanufactured monoclonal antibodies (mAbs) were investigated, contained inside instrumented Versapaks, and flown in a Skylift (Mugin) V50 vertical take-off and landing drone through seven phases of flight, (take-off, hover, transition, cruise, transition, hover, and landing). Storage specifications (2–8°C) were met, and any vibrations emanating from the drone and transmitted through the packaging during flight were monitored using accelerometers. Vibration occurred largely above 44 Hz which was consistent with rotor speeds during operation and was significantly greater in amplitude during transition than in forward flight or in hover. Bench experiments validated assurance practices, exploring the edge-of-quality failure by applying extremes of rotational vibration to the mAbs. Aggregation and fragmentation represented a loss of quality in the mAbs and would pose a risk to patient safety. No significant difference was identified in the aggregation and fragmentation of all flown mAbs samples, indicating structural integrity. Flown mAbs in their infusion bags had similar particle sizes compared to controls, (Bevacizumab 11.8±0.17 nm vs. 11.6±0.05 nm, Trastuzumab 11.2±0.05 nm vs. 11.3±0.13 nm, Rituximab 11.4±0.27 nm vs. 11.5±0.05 nm) and aggregate content (Bevacizumab 1.25±0.03% vs 1.32±0.02% p = 0.11, Trastuzumab 0.15±0.06% vs. 0.16±0.06% p = 0.75, Rituximab 0.11±0.02% vs. 0.11±0.01% p = 0.73). The quality of the three mAbs was assured, suggesting that the V50 drone did not induce sufficient levels of vibration to adversely affect their quality.
Funder
Department for Transport
Engineering and Physical Sciences Research Council
King’s-China Scholarship Council
Publisher
Public Library of Science (PLoS)
Reference43 articles.
1. Lord Carter of Coles. Transforming NHS pharmacy aseptic services in England. 2020 p. 51. https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/931195/aseptic-pharmacy.pdf
2. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents;E Chatelut;Br J Cancer,2012
3. Monoclonal antibodies: magic bullets with a hefty price tag;AF Shaughnessy;BMJ,2012
4. Monoclonal Antibody Monitoring: Clinically Relevant Aspects, A Systematic Critical Review;M Regazzi;Ther Drug Monit,2020
5. Opportunities to significantly reduce expenditure associated with cancer drugs;PJ Gilbar;Future Oncol,2017
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献