Abstract
Background
Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.
Methods
We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99th percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.
Results
The median hs-cTn I/T ratio was 3.45 (25th, 75th percentiles 1.80–6.59) in type 1 MI patients (n = 408 ☯46.0%]), 1.18 (0.81–1.90) in type 2 MI patients (n = 56 ☯6.3%]) and 0.67 (0.39–1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 ☯95% confidence interval 0.86–0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 ☯95% confidence interval 0.74–0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.
Conclusions
The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
Publisher
Public Library of Science (PLoS)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献