Evaluation of agreement between a noninvasive method for real-time measurement of critical blood values with a standard point-of-care device

Author:

Ettrich Rudi H.ORCID,Caballero JoshuaORCID,Sakharkar Prashant,Ahmed Sultan,Hurlston Traci,Parmar Jayesh,Deb SubrataORCID

Abstract

The purpose of this work was to investigate the degree of agreement between two distinct approaches for measuring a set of blood values and to compare comfort levels reported by participants when utilizing these two disparate measurement methods. Radial arterial blood was collected for the comparator analysis using the Abbott i-STAT® POCT device. In contrast, the non-invasive proprietary DBC methodology is used to calculate sodium, potassium, chloride, ionized calcium, total carbon dioxide, pH, bicarbonate, and oxygen saturation using four input parameters (temperature, hemoglobin, pO2, and pCO2). Agreement between the measurement for a set of blood values obtained using i-STAT and DBC methodology was compared using intraclass correlation coefficients, Passing and Bablok regression analyses, and Bland Altman plots. A p-value of <0.05 was considered statistically significant. A total of 37 participants were included in this study. The mean age of the participants was 42.4 ± 13 years, most were male (65%), predominantly Caucasian/White (75%), and of Hispanic ethnicity (40%). The Intraclass Correlation Coefficients (ICC) analyses indicated agreement levels ranging from poor to moderate between i-STAT and the DBC’s algorithm for Hb, pCO2, HCO3, TCO2, and Na, and weak agreement for pO2, HSO2, pH, K, Ca, and Cl. The Passing and Bablok regression analyses demonstrated that values for Hb, pO2, pCO2, TCO2, Cl, and Na obtained from the i-STAT did not differ significantly from that of the DBC’s algorithm suggesting good agreement. The values for Hb, K, and Na measured by the DBC algorithm were slightly higher than those obtained by the i-STAT, indicating some systematic differences between these two methods on Bland Altman Plots. The non-invasive DBC methodology was found to be reliable and robust for most of the measured blood values compared to invasive POCT i-STAT device in healthy participants. These findings need further validation in larger samples and among individuals afflicted with various medical conditions.

Funder

Digital Blood Corporation

Publisher

Public Library of Science (PLoS)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3