Reliability of radiologists’ first impression when interpreting a screening mammogram

Author:

Gandomkar ZibaORCID,Siviengphanom SomphoneORCID,Suleiman Mo’ayyad,Wong Dennis,Reed Warren,Ekpo Ernest U.,Xu DongORCID,Lewis Sarah J.,Evans Karla K.,Wolfe Jeremy M.,Brennan Patrick C.

Abstract

Previous studies showed that radiologists can detect the gist of an abnormality in a mammogram based on a half-second image presentation through global processing of screening mammograms. This study investigated the intra- and inter-observer reliability of the radiologists’ initial impressions about the abnormality (or "gist signal"). It also examined if a subset of radiologists produced more reliable and accurate gist signals. Thirty-nine radiologists provided their initial impressions on two separate occasions, viewing each mammogram for half a second each time. The intra-class correlation (ICC) values showed poor to moderate intra-reader reliability. Only 13 radiologists had an ICC of 0.6 or above, which is considered the minimum standard for reliability, and only three radiologists had an ICC exceeding 0.7. The median value for the weighted Cohen’s Kappa was 0.478 (interquartile range = 0.419–0.555). The Mann-Whitney U-test showed that the "Gist Experts", defined as those who outperformed others, had significantly higher ICC values (p = 0.002) and weighted Cohen’s Kappa scores (p = 0.026). However, even for these experts, the intra-radiologist agreements were not strong, as an ICC of at least 0.75 indicates good reliability and the signal from none of the readers reached this level of reliability as determined by ICC values. The inter-reader reliability of the gist signal was poor, with an ICC score of 0.31 (CI = 0.26–0.37). The Fleiss Kappa score of 0.106 (CI = 0.105–0.106), indicating only slight inter-reader agreement, confirms the findings from the ICC analysis. The intra- and inter-reader reliability analysis showed that the radiologists’ initial impressions are not reliable signals. In particular, the absence of an abnormal gist does not reliably signal a normal case, so radiologists should keep searching. This highlights the importance of "discovery scanning," or coarse screening to detect potential targets before ending the visual search.

Funder

National Health and Medical Research Council

National Breast Cancer Foundation

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3