Machine learning-based prediction of intraoperative hypoxemia for pediatric patients

Author:

Park Jung-Bin,Lee Ho-Jong,Yang Hyun-LimORCID,Kim Eun-Hee,Lee Hyung-ChulORCID,Jung Chul-WooORCID,Kim Hee-SooORCID

Abstract

Background Reducing the duration of intraoperative hypoxemia in pediatric patients by means of rapid detection and early intervention is considered crucial by clinicians. We aimed to develop and validate a machine learning model that can predict intraoperative hypoxemia events 1 min ahead in children undergoing general anesthesia. Methods This retrospective study used prospectively collected intraoperative vital signs and parameters from the anesthesia ventilator machine extracted every 2 s in pediatric patients undergoing surgery under general anesthesia between January 2019 and October 2020 in a tertiary academic hospital. Intraoperative hypoxemia was defined as oxygen saturation <95% at any point during surgery. Three common machine learning techniques were employed to develop models using the training dataset: gradient-boosting machine (GBM), long short-term memory (LSTM), and transformer. The performances of the models were compared using the area under the receiver operating characteristics curve using randomly assigned internal testing dataset. We also validated the developed models using temporal holdout dataset. Pediatric patient surgery cases between November 2020 and January 2021 were used. The performances of the models were compared using the area under the receiver operating characteristic curve (AUROC). Results In total, 1,540 (11.73%) patients with intraoperative hypoxemia out of 13,130 patients’ records with 2,367 episodes were included for developing the model dataset. After model development, 200 (13.25%) of the 1,510 patients’ records with 289 episodes were used for holdout validation. Among the models developed, the GBM had the highest AUROC of 0.904 (95% confidence interval [CI] 0.902 to 0.906), which was significantly higher than that of the LSTM (0.843, 95% CI 0.840 to 0.846 P < .001) and the transformer model (0.885, 95% CI, 0.882–0.887, P < .001). In holdout validation, GBM also demonstrated best performance with an AUROC of 0.939 (95% CI 0.936 to 0.941) which was better than LSTM (0.904, 95% CI 0.900 to 0.907, P < .001) and the transformer model (0.929, 95% CI 0.926 to 0.932, P < .001). Conclusions Machine learning models can be used to predict upcoming intraoperative hypoxemia in real-time based on the biosignals acquired by patient monitors, which can be useful for clinicians for prediction and proactive treatment of hypoxemia in an intraoperative setting.

Funder

the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3