A comparative field evaluation of six medicine quality screening devices in Laos

Author:

Caillet CélineORCID,Vickers SerenaORCID,Zambrzycki StephenORCID,Fernández Facundo M.ORCID,Vidhamaly VayoulyORCID,Boutsamay KemORCID,Boupha Phonepasith,Peerawaranun Pimnara,Mukaka MavutoORCID,Newton Paul N.

Abstract

Background Medicine quality screening devices hold great promise for post-market surveillance (PMS). However, there is little independent evidence on their field utility and usability to inform policy decisions. This pilot study in the Lao PDR tested six devices’ utility and usability in detecting substandard and falsified (SF) medicines. Methodology/principal findings Observational time and motion studies of the inspections by 16 Lao medicine inspectors of 1) the stock of an Evaluation Pharmacy (EP), constructed to resemble a Lao pharmacy, and 2) a sample set of medicines (SSM); were conducted without and with six devices: four handheld spectrometers (two near infrared: MicroPHAZIR RX, NIR-S-G1 & two Raman: Progeny, Truscan RM); one portable mid-infrared spectrometer (4500a), and single-use paper analytical devices (PAD). User experiences were documented by interviews and focus group discussions. Significantly more samples were wrongly categorised as pass/fail with the PAD compared to the other devices in EP inspections (p<0.05). The numbers of samples wrongly classified in EP inspections were significantly lower than in initial visual inspections without devices for 3/6 devices (NIR-S-G1, MicroPHAZIR RX, 4500a). The NIR-S-G1 had the fastest testing time per sample (median 93.5 sec, p<0.001). The time spent on EP visual inspection was significantly shorter when using a device than for inspections without devices, except with the 4500a, risking missing visual clues of samples being SF. The main user errors were the selection of wrong spectrometer reference libraries and wrong user interpretation of PAD results. Limitations included repeated inspections of the EP by the same inspectors with different devices and the small sample size of SF medicines. Conclusions/significance This pilot study suggests policy makers wishing to implement portable screening devices in PMS should be aware that overconfidence in devices may cause harm by reducing inspectors’ investment in visual inspection. It also provides insight into the advantages/limitations of diverse screening devices in the hands of end-users.

Funder

Asian Development Bank

Wellcome Trust

Publisher

Public Library of Science (PLoS)

Subject

Infectious Diseases,Public Health, Environmental and Occupational Health

Reference42 articles.

1. World Health Organization. WHO Global Surveillance and Monitoring System for substandard and falsified medical products: executive summary. [Internet]. Geneva, Switzerland; 2017. Available from: WHO/EMP/RHT/SAV/2017.01

2. SF Medical Products Group, Essential Medicines and Health Products WHO. WHO Member State Mechanism on Substandard/Spurious/Falsely-Labelled/Falsified/Counterfeit (SSFFC) Medical Products. In: Seventieth World Health Assembly [Internet]. Geneva, Switzerland; 2017. p. A70/23: 33–36. Available from: http://www.who.int/medicines/regulation/ssffc/A70_23-en1.pdf?ua=1

3. Global landscape assessment of screening technologies for medicine quality assurance: stakeholder perceptions and practices from ten countries.;L Roth;Global Health,2018

4. Field detection devices for screening the quality of medicines: a systematic review;S Vickers;BMJ Glob Heal,2018

5. Technologies for detecting falsified and substandard drugs in low and middle-income countries.;S Kovacs;PLoS One.,2014