Affiliation:
1. 1 School of Energy and Environment, Southeast University, Nanjing 210096, China
Abstract
AbstractExcessive discharge of phosphorus can produce eutrophication in aquatic environments, damaging public health, the living environment, and the economy. The conventional mechanical–biological phosphorus removal methods are not suitable for small rural domestic sewage due to the features of small scale, scattered distribution, intermittent emission, and large fluctuation. This work evaluated electrocoagulation (EC) with industrial steel as electrodes on small rural domestic sewage. Results showed that the best performance was achieved at a current density of 1 mA/cm2, electrode distance of 2 cm, electrode number of 2, pH of 7, and Hydraulic Retention Time of 30 min, respectively. Under optimum conditions, the EC process removed 93.91% phosphorus while consuming around 0.25 kWh/m3 of electricity. In addition, the electrode passivation of EC was further investigated; the long-term research found that the phosphorus removal efficiency only decreased by 4.34% after 10 days of continuous flow operation, and the operational energy consumption was 0.07 kWh/m3 at a Cl– concentration of 500 mg/L.
Funder
Innovative Research Group Project of the National Natural Science Foundation of China
Subject
Water Science and Technology,Environmental Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献