In Vitro Evaluation of the Primary Stability of Short and Conventional Implants

Author:

de Oliveira Guilherme José Pimentel Lopes1,Barros-Filho Luiz Antônio Borelli1,Barros Luiz Antônio Borelli2,Queiroz Thalita Pereira3,Marcantonio Elcio1

Affiliation:

1. Section of Periodontology, Department of Diagnosis and Surgery, School of Dentistry at Araraquara-Universidade Estadual Paulista, Araraquara, SP, Brazil.

2. Section of Clinics, Department of Oral Social Health, School of Dentistry at Araraquara- Universidade Estadual Paulista, Araraquara, SP, Brazil.

3. Department of Health Sciences, Dental School, University Center of Araraquara–Araraquara, São Paulo, Brazil.

Abstract

The objective of this study was to evaluate the primary stability of short and conventional dental implants with different platform types at different site densities in vitro. One hundred twenty implants were placed in polyurethane blocks that simulate different bone densities (bone types I and IV). The implants were divided into 10 groups, with 12 implants each according to the type of prosthetic connections (external hexagon, EH; morse taper, MT) and size of the implants (conventional: 4 × 10 mm; short: 5 × 5, 5.5 × 5, 5 × 6, and 5.5 × 6 mm). Insertion torque and resonance frequency analyses were performed to evaluate the primary stability. The Kruskal-Wallis test complemented by Dunn's test and the Mann-Whitney test were used for statistical analysis. These tests were applied at the confidence level of 95% (P < .05). The implants installed in blocks with density type IV exhibited reduced insertion torque compared with implants placed in blocks with density type I. Short implants with EH exhibited increased insertion torque compared with short implants with MT in blocks with bone density type I. In general, implants installed in blocks with density type I exhibited greater primary stability. The short implants with EH with a 5.5-mm diameter and the short implants with MT with a 5-mm diameter exhibited reduced primary stability. No differences between short and conventional implants were noted. Short implants have primary stability and insertion torque at least equivalent to conventional implants irrespective of the platform type and density of the site.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3