Dynamic measurement of human capillary blood pressure

Author:

Williams S. A.1,Wasserman S.1,Rawlinson D. W.1,Kitney R. I.2,Smaje L. H.1,Tooke J. E.1

Affiliation:

1. Department of Physiology, Charing Cross and Westminster Medical School, London

2. Department of Engineering in Medicine, Imperial College, London

Abstract

1. Capillary blood pressure was measured in man using a dynamic servo-nulling system and direct micropuncture. This enabled assessments of the normal variations in pressure which influence fluid filtration and reabsorption. 2. Seventy-eight capillaries in 19 subjects were punctured in one of three positions around the capillary loop with the hand at the level of the sternal angle. Mean pressure around the loop fell from 37.7 ± 3.7 mmHg (arteriolar limb, mean ± sem, n = 12) to 19.4 ± 1.0 mmHg (apex, n = 25) to 14.6 ± 0.5 mmHg (venular limb, n = 41) at skin temperatures of 18.7–33.1°C. These values agree closely with Landis' original studies in 1930 [E. Landis (1930) Heart, 15, 209–228]. 3. The mean filtration/reabsorption state of any particular capillary limb was not static because of cardiac, vasomotor and respiratory fluctuations in capillary pressure. From a total of 38 capillaries in which recordings were analysed for 30 s, the fluctuations in pressure were such that 27 capillaries probably had periods of both filtration and reabsorption. 4. Computerized superimposition and coherent averaging of trains of capillary pulses enabled an accurate description of the pulse waveform to be made in three capillaries. This was remarkably similar to waveforms from the radial artery, albeit at reduced amplitude (average 3.6 ± 3.4 mmHg, mean ± sd overall). The time for the pulse to travel between the radial artery and the finger capillary was approximately 10 ms, which implies a propagation velocity of several metres per second. 5. Fourteen long recordings of capillary pressure (mean 154 s) were subjected to computerized Fourier analysis and cross-correlation with other parameters. Low frequency fluctuations between 0.02 and 0.2 Hz (0.086 ± 0.05 Hz, mean ± sd) correlated closely with vasomotion in simultaneously recorded (laser-Doppler) skin blood flow (0.080 ± 0.5 Hz), although they were not synchronous. Higher frequencies between 0.2 and 0.6 Hz (0.28 ± 0.03 Hz) correlated well with respiration (0.29 ± 0.03 Hz), were synchronous and probably relate to respiratory fluctuations in venous pressure. The dynamic system has thus enabled us to describe the considerable variations in normal capillary pressure and to relate this variability to physiological influences.

Publisher

Portland Press Ltd.

Subject

General Medicine

Cited by 56 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3