Abstract

Venous occlusion plethysmography is commonly used as a tool to assess BF (blood flow) and VR (vascular resistance) at baseline and during PORH (post-occlusive reactive hyperaemia). However, little is known about the reproducibility of this method. The purpose of the present study was to investigate short- (hours) and medium (week)-term reproducibility of forearm, calf and thigh BF and VR at baseline and during PORH. Reproducibility was assessed by the CV (coefficient of variation). In eight subjects, baseline BF and VR of the forearm, calf and thigh were measured using venous occlusion plethysmography (50 mmHg). PORH and minimal VR were measured after 13 min of arterial occlusion (220 mmHg). Reproducibility of baseline forearm and calf BF was acceptable and in agreement with previous studies (CV, 12.9–21.2%). Short- and medium-term reproducibility of thigh BF was good (CV, 5.9% and 8.7% respectively). Baseline VR showed acceptable-to-good reproducibility for forearm, calf and thigh (8.3–22.5%). Forearm PORH showed a CV of 6.1% (short term) and 8.6% (medium term); this was 6.1% (short term) and 6.4% (medium term) for the calf and 6.4% (short term) and 8.0% (medium term) for the thigh. Minimal VR showed good-to-acceptable reproducibility (CV, 6.1–11.7%). In conclusion, forearm, calf and thigh BF and PORH measured by plethysmography have an acceptable-to-good short- and medium-term reproducibility. Short- and medium-term reproducibility of forearm and calf baseline BF are acceptable and thigh baseline BF has a good short- and medium-term reproducibility. Therefore plethysmography is a suitable low-cost tool to assess thigh baseline BF and PORH.

Publisher

Portland Press Ltd.

Subject

General Medicine

Reference45 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3