Effect of degree of conversion on in vivo biocompatibility of flowable resin used for bioprotection of mini-implants

Author:

Lacerda-Santos Rogério1,de Meneses Izaura Helena Chaves2,de Morais Sampaio Gêisa Aiane2,Pithon Matheus Melo3,Alves Polliana Muniz4

Affiliation:

1. Professor, Degree Program in Dentistry, Federal University of Campina Grande, Patos, Brazil.

2. Master’s Student, Graduate Program in Dentistry, Federal University of Paraíba, João Pessoa, Brazil.

3. Professor, Degree Program in Dentistry, State University of Southwest Bahia, Jequié, Brazil.

4. Professor, Graduate Program in Dentistry, State University of Paraíba, Campina Grande, Brazil.

Abstract

ABSTRACT Objective:  To test the hypothesis that there is no difference between the biocompatibility and degree of monomer conversion of flowable resins used as bioprotective materials of orthodontic mini-implants. Materials and Methods:  Forty-eight male Wistar rats were divided into four groups (n  =  12). Group Control (polyethylene), Group Wave, Group Top Comfort, and Group Filtek. The animals were sacrificed after time intervals of 7, 15, and 30 days and tissues were analyzed under optical microscopy for inflammatory infiltrate, edema, necrosis, granulation tissue, multinucleated giant cells, and collagen formation. The degree of conversion was evaluated by the Fourier method. Biocompatibility and degree of conversion were evaluated by the Kruskal-Wallis and Dunn tests, and analysis of variance and the Tukey test, respectively (P < .05). Results:  An intense inflammatory infiltrate was observed on the seventh day, with Groups Top Comfort and Filtek differing statistically from Group Control (P  =  .016). Edema, necrosis, granulation tissue, and giant cells showed greater expressiveness at 7 days, without statistical difference between them (P > .05). For the presence of collagen fibers, Group Top Comfort was shown to differ statistically from Group Control (P  =  .037) at 15 days and from Groups Filtek and Control (P  =  .008) at 30 days. Monomer conversion ranged from 62.3% in Group Top Comfort at 7 days to 79.1% in Group Filtek at 30 days. Conclusions:  The hypothesis was rejected. The resin Top Comfort demonstrated lower tissue repair capacity with a lower number of collagen fibers compared with Filtek and Wave resins. The resin Top Comfort showed the lowest conversion values during the experiment.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3