Abstract
Air flow is of great importance in terms of energy efficiency and homogeneity of the cooled package temperatures in open type refrigerated display cabinets (RDCs). Deflectors are critical components for air curtains which are provides air directioning to air channel and grill. A new deflector structure was investigated to increase the performance of the air curtain in this study. Current design deflector structure (Design 1) and new design deflector structure (Design 2) were compared for temperatures of air off-air on and energy consumption parameters. Airflow in the new design deflector structure was tested under Class-3 conditions (25 °C temperature and %60 relative humidity) with ISO 23953-2 2015 standard. According to the results obtained the data compared with the current design deflector structure. The thermal performance has been increased by reducing the temperature of the air off by 1.2 °C on average, the air on temperature by an average of 2.05 °C and the average package temperature by %17.8 with the new deflector design. Cooling performance was increased using new deflector structure with effective airflow between the air off and air on. In addition, thanks to Design 2, the annual energy consumption of RDC has been reduced by 10.17% and accordingly the CO2 emissions released to the environment have been reduced at the same rate.
Publisher
Orclever Science and Research Group
Reference17 articles.
1. Laguerre, O., Operation (2015), Design and performance of retail display cabinets. Evans, J,A, Foster, A,M, editors. Sustainable Retail Refrigeration, UK: Wiley Blackwell, 17-31. 2. Chen, Y,G, (2009). Parametric evaluation of refrigerated air curtains for thermal insulation. International Journal of Thermal Sciences, 48(10), 1988-1996. 3. Wu, X, Gao, Z, Meng, H, Wang, Y, Cheng, C. (2020). Experimental study on the uniform distribution of gas-liquid two-phase flow in a variable-aperture deflector in a parallel flow heat exchanger. International Journal of Heat and Mass Transfer, 150, 119353. 4. Li, X., Wu, F., Tao, Y., Yang, M., Xu, R., Vainchtein, D. (2022). Numerical investigation of flow deflectors for the improvement of condensing air flux through the air-conditioning unit on high-velocity trains. Building and Environment, 215, 108949. 5. Gao, R., Li, H., Li, A., Liu, K., Yu, S., Deng, B. (2019). Applicability study of a deflector in ventilation and air conditioning duct tees based on an analysis of energy dissipation. Journal of Wind Engineering and Industrial Aerodynamics, 184, 256-264.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|