An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma

Author:

Salzmann Linda1,Spescha Tino1,Singh Neeraj2,Schierscher Tobias1,Bachmann Martina2,Bauland Friederike3,Geistanger Andrea2,Risch Lorenz1ORCID,Geletneky Christian2,Seger Christoph1,Taibon Judith2

Affiliation:

1. Dr. Risch Ostschweiz AG , Buchs , Switzerland

2. Roche Diagnostics GmbH , Penzberg , Germany

3. Chrestos Concept GmbH & Co. KG , Essen , Germany

Abstract

Abstract Objectives We developed an isotope dilution (ID)-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for lamotrigine in human serum and plasma, using quantitative nuclear magnetic resonance-characterized reference standards to ensure traceability to the International System of Units. Methods A sample preparation protocol based on protein precipitation combined with LC-MS/MS analysis using a C18 column for chromatographic separation was established for the quantification of lamotrigine in human serum and plasma. Assay validation was performed according to current guidelines. Spiked serum and plasma samples were used to assess selectivity and specificity; a post-column infusion experiment and comparison of standard line slopes were performed to ascertain possible matrix effects. Precision and accuracy were determined in a 5 days validation experiment. Measurement uncertainty was determined per the Guide to the Expression of Uncertainty in Measurement. Results The method allowed the quantification of lamotrigine in serum and plasma in a range of 0.600–24.0 μg/mL without any observable matrix effects. The relative mean bias (n=6) ranged from 1.7 to 3.7%; intermediate precision, including variances in between-day, -calibration, and -injection, was ≤2.4%, independent of the level and matrix. Total measurement uncertainty for a single measurement was ≤2.6%; expanded uncertainty was ≤5.2% (coverage factor k=2). Conclusions This candidate RMP based on ID-LC-MS/MS provides a traceable and reliable platform for the standardization of routine assays and the evaluation of clinical samples.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3