An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine-10,11-epoxide in human serum and plasma

Author:

Schierscher Tobias1,Singh Neeraj2,Kobel Anja1,Wild Janik1,Bauland Friederike3,Geistanger Andrea2,Risch Lorenz1ORCID,Geletneky Christian2,Seger Christoph1,Taibon Judith2

Affiliation:

1. 58117 Dr. Risch Ostschweiz AG , Buchs , Switzerland

2. 111618 Roche Diagnostics GmbH , Penzberg , Germany

3. 123305 Chrestos Concept GmbH & Co. KG , Essen , Germany

Abstract

Abstract Objectives A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. Methods To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. Results The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400–12.0 μg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. Conclusions In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. LC-MS/MS random access automation – a game changer for the 24/7 clinical laboratory;Clinical Chemistry and Laboratory Medicine (CCLM);2024-05-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3