Self-sampling of blood using a topper and pediatric tubes; a prospective feasibility study for PSA analysis using 120 prostate cancer patients

Author:

van den Brink Nicas1,Even Rixt2,Delic Enver2,van Hellenberg Hubar-Fisher Sarah1,van Rossum Huub H.12

Affiliation:

1. Self Safe Sure Blood Collections B.V. , Amsterdam , The Netherlands

2. Department of Laboratory Medicine , The Netherlands Cancer Institute , Amsterdam , The Netherlands

Abstract

Abstract Objectives Self-collection of blood for diagnostic purposes by blood collection assist devices (BCAD) has gained a lot of momentum. Nonetheless, there are a lack of studies demonstrating the feasibility and reliability of self-collecting capillary blood for routine (immuno)chemistry testing. In this study we describe the topper technology together with pediatric tubes to enable self-collection of blood and investigated its feasibility for PSA testing by prostate cancer patients. Methods A total of 120 prostate cancer patients for which a routine follow-up PSA test was requested, were included in this study. Patients received instruction materials and the blood-collection device consisting of a topper, pediatric tube and base-part, and performed the blood collection procedure themselves. Afterwards a questionnaire was filled-in. Finally, PSA was measured on a Roche Cobas Pro. Results The overall self-sampling success rate was 86.7 %. Furthermore, when specified per age category, a 94.7 % success rate for patients under 70 years and a 25 % success rate for patients of 80 years and older was observed. Venous and self-collected PSA were highly comparable when analyzed by Passing–Bablok regression with a slope of 0.99 and intercept of 0.00011, Spearmans correlation coefficient (0.998) and average self-collected PSA recovery of 99.8 %. Conclusions Evidence is presented that self-collected capillary blood by topper and pediatric tube from the finger is feasible, particularly for patients under 70 years. Furthermore, capillary blood self-sampling did not compromise any of the PSA test results. Future validation in a real-world setting, without supervision and including sample stability and logistics, is required.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Proof-of-concept study: Remote capillary blood collection for hCG analysis in early pregnancy;European Journal of Obstetrics & Gynecology and Reproductive Biology;2024-09

2. Blood self-sampling devices: innovation, interpretation and implementation in total lab automation;Clinical Chemistry and Laboratory Medicine (CCLM);2024-06-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3