Towards 50 years of platelet function analyser (PFA) testing

Author:

Favaloro Emmanuel J.123ORCID,Pasalic Leonardo124ORCID,Lippi Giuseppe5ORCID

Affiliation:

1. Haematology , Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital , Westmead , NSW , Australia

2. Sydney Centres for Thrombosis and Haemostasis , Westmead , NSW , Australia

3. Faculty of Science and Health , Charles Sturt University , Wagga Wagga , NSW , Australia

4. Westmead Clinical School , University of Sydney , Westmead , NSW , Australia

5. Section of Clinical Biochemistry and School of Medicine , University of Verona , Verona , Italy

Abstract

Abstract The platelet function analyser (PFA) is a prevalent platelet function screening instrument, and comes in two models–the original PFA-100 and the contemporary PFA-200. The instruments have ‘identical’ output, being a ‘closure time’ (CT). Moreover, normal reference ranges provided by the manufacturer, for the specific test cartridges, are the same for both models. There are three different types of test cartridge: collagen/epinephrine (C/Epi), collagen/adenosine diphosphate (C/ADP), and “Innovance PFA P2Y” (only available in certain geographical locations). The PFA-100 was released in the mid 1990s, and so is approaching 50 years of age. The PFA-200, released in some locations in the mid 2010s, is destined to eventually replace the PFA-100, but is not yet available in the USA. The test system is highly sensitive to von Willebrand disease (VWD; C/Epi and C/ADP) and to aspirin therapy (C/Epi only), but only has moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. Accordingly, recommendations for use for screening platelet function vary according to user experience. Some workers have alternatively used the PFA to assess thrombosis risk or pre-operative bleeding risk. In this review, we provide an overview of the history of PFA, and summarise its current clinical utility.

Funder

NSW Health

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3