Diagnostic accuracy of Siemens SARS-CoV-2 Antigen (CoV2Ag) chemiluminescent immunoassay for diagnosing acute SARS-CoV-2 infection: a pooled analysis

Author:

Lippi Giuseppe123ORCID,Henry Brandon M.124,Plebani Mario125ORCID

Affiliation:

1. IFCC Task Force on COVID-19 , Milano , Italy

2. IFCC WG on SARS-CoV-2 variants , Milano , Italy

3. Section of Clinical Biochemistry and School of Medicine , University of Verona , Verona , Italy

4. Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children’s Hospital Medical Center , Cincinnati OH , USA

5. Department of Medicine , University of Padova , Padova , Italy

Abstract

Abstract Background This article provides a critical literature review and pooled analysis of diagnostic accuracy of the fully-automated Siemens SARS-CoV-2 Antigen (CoV2Ag) chemiluminescent immunoassay for diagnosis of acute SARS-CoV-2 infections. Methods An electronic search was conducted in Scopus, PubMed and medRxiv using the keywords [“Siemens AND CoV2Ag”] OR [“Siemens AND SARS-CoV-2 AND antigen”] for capturing studies that investigated the accuracy of Siemens CoV2Ag for diagnosing acute SARS-CoV-2 infection against a reference SARS-CoV-2 molecular test. The retrieved information was used for constructing a 2 × 2 table and for calculating pooled diagnostic sensitivity, specificity, Summary Receiver Operating Characteristic Curve (SROC) and Agreement. This study followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) reporting checklist. Results Four studies totalling 1,310 respiratory samples (612 with high viral load) were finally included in our analysis. The cumulative area under the curve, accuracy, sensitivity, specificity, were 0.964 (95% CI, 0.957–0.971), 86.9% (95% CI, 84.9–88.7%), 0.79 (95% CI, 0.76–0.82) and 0.98 (95% CI, 0.96–0.99), respectively. The negative (NPV) and positive (PPV) predictive values were 0.77 (0.74–0.79) and 0.98 (95% CI, 0.96–99), respectively. The diagnostic sensitivity in samples with high viral load (i.e., Ct<29–30) was 0.95 (95% CI, 0.93–0.97). Conclusions The Siemens CoV2Ag fully-automated and high-throughput immunoassay approximates the minimum performance criteria for general SARS-CoV-2 antigen testing and displays excellent performance in samples with high viral load, thus representing a valuable screening solution for risk assessment in COVID-19 and for limiting viral spread.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3