An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma

Author:

Engel Anett1,Ruhe Lena1,Singh Neeraj2,Wright Jo Anne2,Liesch Franziska2,Bauland Friederike3,Ostermann Annika I.1,Sumalowitsch Tamara1,Schweinsberg Vincent J. T.4,Geistanger Andrea2,Hegel Johannes Kolja1,Geletneky Christian2,Taibon Judith2

Affiliation:

1. Department of Studies, Collaborations and Innovation Management , Labor Berlin – Charité Vivantes Services GmbH , Berlin , Germany

2. Roche Diagnostics GmbH , Penzberg , Germany

3. Chrestos Concept GmbH & Co. KG , Essen , Germany

4. Department of Laboratory Medicine and Toxicology , Labor Berlin – Charité Vivantes GmbH , Berlin , Germany

Abstract

Abstract Objectives To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma. Methods Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed-phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines. Results The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200–5,700 ng/mL (0.01584–12.54 μmol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was ≤4.3% and repeatability 1.5–2.1% for all analyte concentrations. Bias was −3.0 to 2.1% for samples within the measuring range and 0.8–4.5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was ≤3.4%. Conclusions This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.

Funder

Roche Diagnostics GmbH

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3