A sensitive LC-MS/MS methotrexate assay capable of assessing adherence to methotrexate therapy in rheumatoid arthritis

Author:

McTaggart Malcolm P.1ORCID,Bluett James23,Keevil Brian G.14

Affiliation:

1. Department of Clinical Biochemistry, Pathology , Wythenshawe Hospital, Manchester University NHS Foundation Trust , Manchester , UK

2. NIHR Manchester Biomedical Research Centre , Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre , Manchester , UK

3. Versus Arthritis Centre for Genetics and Genomics, Centre for Musculoskeletal Research , The University of Manchester , Manchester , UK

4. Department of Clinical Biochemistry , Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre , Manchester , UK

Abstract

Abstract Objectives To develop a sensitive liquid chromatography-tandem mass spectrometry method capable of measuring serum methotrexate in patients with rheumatoid arthritis to assess adherence to drug treatment. Methods Isotopically labelled internal standard and deionised water were added to sample prior to solid phase extraction using a Waters Oasis Max ion-exchange 96-well plate. Following extraction, samples were analysed by LC-MS/MS on a TQS-micro mass spectrometer. Results Mean recovery was 107 % for four different concentrations of methotrexate spiked into seven patient samples, whilst post extraction spiking gave a mean recovery of 100 %. Between-batch and within-batch CVs were ≤6 % at three different concentrations of methotrexate in fresh frozen plasma. Mean bias was <5 % for between-batch and within batch analysis at three different weighed in concentrations of methotrexate certified reference material. The lower limit of quantification of the assay was 0.1 nmol/L with linearity up to approximately 100 nmol/L. Dilution linearity studies were used to validate the dilution of patient samples prior to analysis. There was no significant interference in the method from lipaemia, haemolysis or icterus. Conclusions A sensitive LC-MS/MS assay for methotrexate has been developed and validated. The method has been used to measure methotrexate adherence in patient samples from clinical trials and could be used in future research to assess the ability of the assay as a biofeedback intervention to improve adherence to methotrexate therapy.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3