An evaluation of ten external quality assurance scheme (EQAS) materials for the faecal immunochemical test (FIT) for haemoglobin

Author:

O’Driscoll Shane1ORCID,Piggott Carolyn1ORCID,Bruce Helen12,Benton Sally C.12ORCID

Affiliation:

1. NHS Bowel Cancer Screening Programme Southern Hub , Royal Surrey County Hospital , England , UK

2. Berkshire and Surrey Pathology Services , Royal Surrey County Hospital , England , UK

Abstract

Abstract Objectives External quality assessment schemes (EQAS) are being established worldwide to support the faecal immunochemical test (FIT) for haemoglobin (Hb). FIT is widely used as a screening test for colorectal cancer and increasingly in assessment of patients presenting with symptoms. EQA for FIT is provided in several matrices, each unique to the individual scheme. These include Hb suspended in a faecal-like matrix, lyophilised samples and liquid samples. The aim of this study was to evaluate commercially available EQAS and assess their suitability for use. Methods Ten EQAS provided material for the study. EQA samples were analysed on four quantitative FIT systems. 15 faecal-like matrix samples were loaded per concentration per FIT system. Reconstituted lyophilised samples were examined five times on three separate occasions and liquid samples were examined 10 times per concentration per FIT system. The coefficient of variation (CV) was calculated per concentration of EQA for each FIT system. Results Results from faecal-like matrix schemes had a higher median CV (12.4–19.0%) when compared to those from schemes providing liquid matrices (0.8–2.3%). The spread of CV values was also higher for results from faecal-like matrix schemes with an interquartile range (IQR) 4.4–24.0% vs. liquid IQR range of 0.3–2.5%. Conclusions Hb results from faecal-like matrices, whilst more aligned to a patient or participant sample, are prone to pre-examination variation so do not assess the analytical accuracy of a FIT system. Liquid matrices are not prone to pre-examination variation and are better able to assess the accuracy of a FIT system.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference15 articles.

1. WHO. Cancer key facts 2018, September 12. Available from: https://www.who.int/news-room/fact-sheets/detail/cancer [Accessed 10 Feb 2020].

2. Saito, H. Colorectal cancer screening using immunochemical faecal occult blood testing in Japan. J Med Screen 2006;13 Suppl 1:S6–7.

3. Navarro, M, Nicolas, A, Ferrandez, A, Lanas, A. Colorectal cancer population screening programs worldwide in 2016: an update. World J Gastroenterol 2017;2:3632–42. https://doi.org/10.3748/wjg.v23.i20.3632.

4. National Institute for Health and Care Excellence. Quantitative faecal immunochemical tests to guide referral for colorectal cancer in primary care. Diagnostics guidance DG30. Available from: https://www.nice.org.uk/guidance/dg30 [Accessed 05 Feb 2020].

5. ISO 15189:2012. Medical laboratories - Requirements for quality and competence. Geneva: ISO Publications; 2012.

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献