AbstractIn current clinical practice, plasma and blood glucose are used interchangeably with a consequent risk of clinical misinterpretation. In human blood, glucose is distributed, like water, between erythrocytes and plasma. The molality of glucose (amount of glucose per unit water mass) is the same throughout the sample, but the concentration is higher in plasma, because the concentration of water and therefore glucose is higher in plasma than in erythrocytes. Different devices for the measurement of glucose may detect and report fundamentally different quantities. Different water concentrations in the calibrator, plasma, and erythrocyte fluid can explain some of the differences. Results for glucose measurements depend on the sample type and on whether the method requires sample dilution or uses biosensors in undiluted samples. If the results are mixed up or used indiscriminately, the differences may exceed the maximum allowable error for glucose determinations for diagnosing and monitoring diabetes mellitus, thus complicating patient treatment. The goal of the International Federation of Clinical Chemistry and Laboratory Medicine, Scientific Division, Working Group on Selective Electrodes and Point of Care Testing (IFCC-SD-WG-SEPOCT) is to reach a global consensus on reporting results. The document recommends reporting the concentration of glucose in plasma (in the unit mmol/L), irrespective of sample type or measurement technique. A constant factor of 1.11 is used to convert concentration in whole blood to the equivalent concentration in plasma. The conversion will provide harmonized results, facilitating the classification and care of patients and leading to fewer therapeutic misjudgments.Clin Chem Lab Med 2006;44:1486–90.
Subject
Biochemistry, medical,Clinical Biochemistry,General Medicine
Reference13 articles.
1. Technical evaluation of five glucose meters with data management capabilities;Chance;Am J Clin Pathol,1999
2. al Multicenter study of oxygen - insensitive handheld glucose point - of - care testing in critical care / hospital / ambulatory patients in the United States and Canada;Kost;Crit Care Med,1998
3. Accuracy of devices used for self - monitoring of blood glucose;Johnson;Ann Clin Biochem,1998
4. de Fine Can capillary whole blood glucose and venous plasma glucose measurements be used interchangeably in diagnosis of diabetes mellitus;Stahl;Clin Lab Invest,2002
5. Direct reading glucose electrodes detect the molality of glucose in plasma and whole blood;Fogh;Clin Chim Acta,1990
Cited by
113 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献