Precise glucose measurement in sodium fluoride-citrate plasma affects estimates of prevalence in diabetes and prediabetes

Author:

Heilmann Geronimo12,Trenkamp Sandra12,Möser Clara12,Bombrich Maria12,Schön Martin12,Yurchenko Iryna12,Strassburger Klaus32,Rodríguez Marcos Matabuena4,Zaharia Oana-Patricia125,Burkart Volker12,Wagner Robert125,Roden Michael125ORCID

Affiliation:

1. Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich-Heine-University , Düsseldorf , Germany

2. German Center for Diabetes Research (DZD), Partner Düsseldorf , Düsseldorf , Germany

3. Institute for Biometrics and Epidemiology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich-Heine-University , Düsseldorf , Germany

4. Centro Singular de Investigación en Tecnoloxías Intelixentes, Universidade de Santiago de Compostela , Santiago , Spain

5. Department of Endocrinology and Diabetology, Medical Faculty , Heinrich-Heine-University , Düsseldorf , Germany

Abstract

Abstract Objectives Estimates of glucose concentrations vary among types of blood samples, which impact on the assessment of diabetes prevalence. Guidelines recommend a conversion factor to calculate plasma glucose from measurements of glucose in whole blood. The American Diabetes Association recommends the use of blood drawing tubes containing sodium fluoride (NaF) and citrate, which have not yet been evaluated regarding possible differences in glucose concentration and conversion factors. Thus, we compared glucose measurements in NaF-citrate plasma and venous whole blood and estimated the impact of differences on diabetes and prediabetes prevalence. Methods Glucose differences were calculated by Bland-Altman analysis with pairwise comparison of glucose measurements from whole blood and NaF-citrate plasma (n=578) in clinical studies of the German Diabetes Center. Subsequently, we computed the impact of the glucose difference on diabetes and prediabetes prevalence in the population-based National Health and Nutrition Examination Survey (NHANES). Results Even upon conversion of whole blood to plasma glucose concentrations using the recommended conversion factor, mean glucose concentration difference remained 4.72 % higher in NaF-citrate plasma. Applying the higher glucose estimates, increases the population-based diabetes and prediabetes prevalence by 13.67 and 33.97 % or more than 7.2 and 13 million people in NHANES, respectively. Additional economic burden could be about 20 $ billion per year due to undiagnosed diabetes. Conclusions The recommended conversion factor is not valid for NaF-citrate plasma. Systematic bias of glucose measurements due to sampling type leads to clinically relevant higher estimates of diabetes and prediabetes prevalence.

Funder

German Federal Ministry of Education and Research

Research Network SFB 1116 of the German Research Foundation

German Diabetes Association

German Federal Ministry of Health and the Ministry of Culture and Science of the state of North Rhine-Westphalia

Schmutzler Stiftung

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3