Real-world assessment of the clinical performance of COVID-VIRO ALL IN rapid SARS-CoV-2 antigen test

Author:

Pighi Laura12,Henry Brandon M.3,De Nitto Simone12,Gianfilippi Gianluca4,Salvagno Gian Luca12,Lippi Giuseppe1ORCID

Affiliation:

1. Section of Clinical Biochemistry and School of Medicine , University of Verona , Verona , Italy

2. Service of Laboratory Medicine , Pederzoli Hospital , Peschiera del Garda , Italy

3. Medical Direction , Pederzoli Hospital , Peschiera del Garda , Italy

4. Clinical Laboratory, Division of Nephrology and Hypertension , Cincinnati Children’s Hospital Medical Center , Cincinnati , OH , USA

Abstract

Abstract Objectives Since the external validation of severe acute respiratory syndrome coronavirus 2 antigen rapid diagnostic tests (SARS-CoV-2 RDT-Ags) is a necessary requisite before they can be introduced into routine clinical practice, this study reports the results of a real-world assessment of the clinical performance of the new COVID-VIRO ALL IN device. Methods The study population consisted in 165 outpatients (median age: 43 years, range: 14–68 years; 66.1% females) who had paired nasal and nasopharyngeal samples collected upon hospital presentation. The samples were concomitantly tested with the AAZ-LMB COVID-VIRO ALL IN SARS-CoV-2 RDT-Ag and with Cepheid Xpert Xpress SARS-CoV-2 real-time reverse transcription polymerase chain reaction (RT-PCR). Results The number of subjects with positive RT-PCR results (i.e., mean Ct value <45) was 116 (70.3%), 109 (66.1%) and 86 (52.1%) with mean Ct values <37 and <30, respectively. In all RT-PCR positive samples, COVID-VIRO ALL IN displayed 78.8% agreement, 0.698 sensitivity, 1.000 specificity, 0.583 negative predictive value (NPV) and 1.000 positive predictive value (PPV) compared to RT-PCR. The median Ct value of samples testing positive with COVID-VIRO ALL IN was significantly lower than those testing negative (22.8 vs. 32.2; p<0.001). In samples with high viral load (i.e., Ct value <30), COVID-VIRO ALL IN displayed 92.1% agreement, 0.895 sensitivity, 0.949 specificity, 0.983 NPV and 0.951 PPV compared to RT-PCR. Conclusions Although the diagnostic performance of COVID-VIRO ALL IN do not exactly match those of the manufacturer, its high NPV in high viral load samples would enable fast-track and rapid identification of highly contagious subjects.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,Public Health, Environmental and Occupational Health,Health Policy,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3