Evaluation on the method of restoring the complex communication environment in the field based on the complex low pressure platform simulation platform

Author:

Jiang Jianfeng1,Zhu Wenjun1ORCID

Affiliation:

1. Marketing Service Center, State Grid Shanghai Electric Power Company , 200000 , Shanghai , China

Abstract

Abstract In recent years, with the development of smart grids, people have increasingly high requirements for the safety, stability, and reliability of smart grid operation. In actual operation, smart grids require real-time monitoring and control, while for low-voltage power lines, power line carrier communication is required for data transmission. However, in practical applications on site, the low-voltage power line environment is complex, with ground faults, electrical equipment interference, and other situations that can affect communication quality and reliability, leading to a decrease in the effectiveness of real-time monitoring and control. The research in this paper is based on a complex low voltage platform simulation platform to restore the on-site complex substation communication environment. The purpose is to improve the efficiency of automatic meter reading systems by using various communication methods in low-voltage substations, such as wireless public network point-to-point data transmission, optical fiber communication data transmission, power line carrier data transmission, etc. Automatic meter reading systems are an important means of low voltage substation communication. This article experimentally tested the maximum personnel allocation for meter reading using low voltage carrier communication technology, which was 8 people smaller than the maximum personnel allocation for traditional meter reading, and the minimum personnel allocation was 8 people smaller than the traditional meter reading personnel allocation. The electricity accuracy of meter reading using low voltage carrier communication was up to 96 %, while the electricity accuracy of traditional meter reading was 70 %. The maximum accuracy of line loss statistics for low voltage carrier communication technology meter reading was 90 %, while the maximum accuracy of line loss statistics for traditional meter reading was 68 %. The frequency of load anomalies found in low-voltage carrier communication meter readings within a month ranged from 30 to 60 times, while the traditional meter readings concentrated on 10–25 times. From these data, it is clear that communication meter reading in low-voltage station areas has advantages over traditional meter reading.

Publisher

Walter de Gruyter GmbH

Subject

Energy Engineering and Power Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3