Full-Scale CFD Modeling of Multiphase Flow Distribution in a Packed-bed Absorber with Structured Packing Mellapak 250Y

Author:

Basha Omar M.1,Wang Rui2,Gamwo Isaac K.3,Siefert Nicholas S.3,Morsi Badie I.2

Affiliation:

1. Department of Chemical, Biological and Bio Engineering, North Carolina Agricultural and Technical State University, 329 McNair Hall, 1601 East Market Street, Greensboro, NC 27411-0002, USA

2. Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, PA, USA

3. U.S. Department of Energy, National Energy Technology Laboratory, Research & Innovation Center, Pittsburgh, PA15236, USA

Abstract

AbstractA full-scale multi-environment Eulerian CFD model for a countercurrent packed-bed absorber with structured packing Mellapak 250Y was built in ANSYS Fluent 2019 R1 in order to model CO2 capture using physical solvents. The objective of the model is to predict the overall absorber gas-liquid internal flow profiles within the complex packing geometry, while accurately predicting the hydrodynamic parameters, such as liquid holdup and pressure drop. The gas-solid and gas-liquid drag coefficients were fitted and validated using the following experimental data by Green et al. (2006. “Hydraulic Characterization of Structured Packing via X-ray Computed Tomography”; 2007. “Novel Application of X-ray Computed Tomography: Determination of Gas/liquid Contact Area and Liquid Holdup in Structured Packing.” Industrial & Engineering Chemistry Research 46: 5734–53.): dry pressure drop, irrigated pressure drop, and liquid holdup. The validated CFD model was used to study the effect of liquid distributor design on the liquid distribution in the absorber using three distributors provided with seven, thirteen, and twenty orifices of 0.2 mm diameter. The CFD model predictions revealed that the distributor with the largest number of orifices resulted in the least liquid maldistribution in the absorber, which led to increasing the overall CO2 absorption efficiency in Selexol as a physical solvent. Also, the overall CO2 absorption efficiency decreased with increasing the superficial liquid velocity due to the shorter contact times between CO2 and Selexol in the absorber at higher superficial liquid velocities.

Publisher

Walter de Gruyter GmbH

Subject

General Chemical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3