Author:
Sciacovelli Laura,Secchiero Sandra,Zardo Lorena,D'Osualdo Alessandra,Plebani Mario
Abstract
AbstractTo guarantee excellent performance and service, the process of identifying and treating error risks must be integrated into the total testing process. Quality Assurance Programs (QAPs) represent an important tool that allows us to identify errors and pinpoint any need for further systematic investigations, and to rectify procedures to improve the inputs and processes by which the service is delivered. The models used by the laboratory to assure quality and manage the risk of errors have been modified in line with an approach in which the identification of quality goals and the redefinition of professionals duties and responsibilities are indispensable. Error risk is currently high in some areas of laboratory activity, and QAP is needed now more than ever.The present paper provides some descriptive examples of an approach that can be followed to manage an External Quality Assessment Scheme (EQAS) and quality indicators (QIs), the main tools used by laboratories to assure the quality of their service, for the prevention of error risk. In particular, we describe the correct approach to choose EQAS, to use information from the EQAS report, to design a QI model, and to analyze any QI data. The examples highlight that any well-designed quality system can be ineffective if it is not managed by highly competent professionals with a deep sense of responsibility.Clin Chem Lab Med 2007;45:756–65.
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference12 articles.
1. Quality assessment of interpretative com - menting in clinical chemistry;Lim;Clin Chem,2004
2. Clinical laboratory consultation : appropriate - ness to laboratory medicine;Burke;Clin Chim Acta,2003
3. Identification errors involving clinical laboratories;Valenstein;Arch Pathol Lab Med,2006
4. New roles and responsibilities of NHS chief executives in relation to quality and clinical governance II ii;Sausman;Qual Health Care,2001
5. Interpretative comments and reference ranges in EQA programs as a tool for improving laboratory appro - priateness and effectiveness;Sciacovelli;Clin Chim Acta,2003
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Emerging Technologies Serving Cytopathology;Research Anthology on Architectures, Frameworks, and Integration Strategies for Distributed and Cloud Computing;2021
2. Mobile Health Applications and Cloud Computing in Cytopathology;Research Anthology on Architectures, Frameworks, and Integration Strategies for Distributed and Cloud Computing;2021
3. The Italian External Quality Assessment (EQA) program on urinary sediment by microscopy examination: a 20 years journey;Clinical Chemistry and Laboratory Medicine (CCLM);2020-12-04
4. Impact of water temperature on reconstitution of quality controls for routine hemostasis testing;Diagnosis;2020-02-28
5. From Telecytology to Mobile Cytopathology;Data Analytics in Medicine;2020