Impact of water temperature on reconstitution of quality controls for routine hemostasis testing

Author:

De Nitto Simone1,Salvagno Gian Luca1,Favaloro Emmanuel J.2,Gosselin Robert C.3,Lippi Giuseppe1

Affiliation:

1. Section of Clinical Biochemistry, University of Verona , Verona , Italy

2. Department of Haematology, Sydney Centres for Thrombosis and Haemostasis , Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital , Westmead, New South Wales , Australia

3. Thrombosis and Hemostasis Center, University of California, Davis Health System , Sacramento, CA , USA

Abstract

Abstract Background This study aimed to investigate whether the temperature of distilled water used for reconstituting lyophilized routine internal quality control (IQC) material may influence the process of validation of analytical sessions of routine hemostasis testing. Methods Routine hemostasis testing was performed for 10 consecutive days using two levels of IQC materials dissolved using distilled water at three different temperatures (2–4°C, 22–24°C and 36–38°C). The tests assayed comprised prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FBG), antithrombin (AT), protein C (PC), protein S (PS) and D-dimer (D-Dimer HS 500), using the same ACL TOP 700 hemostasis instrument. Results Overall, 50% (i.e. 7/14) IQC measurements displayed statistically significant bias when lyophilized material was dissolved with distilled water at 3–5°C compared to 22–24°C, and in two instances (level I for both PT and D-dimer) the bias was higher than the quality specifications. Concerning lyophilized material dissolved with distilled water at 36–38°C, 21% (3/14) IQC values displayed a statistically significant bias compared to 22–24°C, and in one instance (level 2 for PT) the bias was higher than the quality specifications. Conclusions The results of this study show that water temperature, as used to dissolve lyophilized IQC material, may represent an important pre-analytical variable in routine hemostasis testing, especially cold temperatures. Laboratory professionals are encouraged to standardize water temperature, preferably between 22 and 24°C, before reconstituting lyophilized IQC materials used to validate routine hemostasis testing.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,Public Health, Environmental and Occupational Health,Health Policy,Medicine (miscellaneous)

Reference28 articles.

1. Lippi G, Mattiuzzi C, Favaloro EJ. Pre-analytical variability and quality of diagnostic testing. Looking at the moon and gazing beyond the finger. NZ J Med Lab Sci 2015;69:4–8.

2. Mok D, Chowdhury S. The strategic management stage of ISO 15189:2012 management system standard: an implementation update. NZ J Med Lab Sci 2019;73:103–7.

3. Plebani M, Favaloro EJ, Lippi G. Patient safety and quality in laboratory and hemostasis testing: a renewed loop? Semin Thromb Hemost 2012;38:553–8.

4. Gosselin RC, Marlar RA, Adcock DM. Assessing quality in the specialized hemostasis laboratory: review and critique of external quality assurance (EQA) programs in the US. Ann Blood 2019;4:16.

5. Miller WG, Erek A, Cunningham TD, Oladipo O, Scott MG, Johnson RE. Commutability limitations influence quality control results with different reagent lots. Clin Chem 2011;57:76–83.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献