Measurement of serum monoclonal components: comparison between densitometry and capillary zone electrophoresis

Author:

Mussap Michele,Pietrogrande Francesco,Ponchia Silvia,Stefani Piero Maria,Sartori Roberto,Plebani Mario

Abstract

AbstractQuantitative measurement of serum monoclonal protein (M-protein) is one of the most important tools for monitoring disease activity in monoclonal gammopathies. The aims of this study were to evaluate serum M-protein quantification by capillary zone electrophoresis (CZE) and to compare results with those obtained by densitometric scanning of high-resolution agarose gel electrophoresis (HRE-AGE). The evaluation was carried out on 82 samples from patients with various monoclonal gammopathies. All the suspected M-proteins were confirmed and characterised by immunofixation on agarose gel (IFE). CZE was performed on a Paragon CZE™ 2000 system (Beckman Coulter). Passing-Bablok regression was: y (CZE)=1.27×(HRE-AGE)–5.21g/L. The correlation coefficient was 0.92. Bland-Altman analysis demonstrated a mean difference of −1.83g/L (95% CI −0.76 to −2.90) with clear evidence of a concentration-related bias. Densitometry gave higher values at low M-spikes (<20g/L), whereas CZE gave higher values at large M-spikes (>20g/L). The concentration-related bias was found to be independent of the immunoglobulin isotype. In conclusion, to compare previous results obtained by M-protein densitometric scanning with those obtained by direct measurement of CZE peaks, the calculation of a univocal transforming factor appears to be unreliable.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference16 articles.

1. Interference of iodinated contrast media in serum capillary zone electrophoresis;Arranz;Clin Chem,2000

2. Evaluation of serum protein separation by capillary electrophoresis : prospective analysis of specimens;Jenkins;J Chromatogr B Biomed Appl,1995

3. Automated multicapillary electrophoresis for analysis of human serum proteins;Gay;Clin Chem,2003

4. A general regression procedure for method transformation Application of linear regression procedures for method comparison studies in clinical chemistry Part III;Bablok;J Clin Chem Clin Biochem,1988

5. Precision and reliability of paraprotein determinations by high - resolution agarose gel electrophoresis;Stemerman;Am J Clin Pathol,1989

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3