Underfilling of vacuum blood collection tubes leads to increased lactate dehydrogenase activity in serum and heparin plasma samples

Author:

Neuwinger Nick12,Meyer zum Büschenfelde Dirk12,Tauber Rudolf12,Kappert Kai13

Affiliation:

1. Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health , Institute of Laboratory Medicine, Clinical Chemistry and Pathobiochemistry , Berlin , Germany

2. Labor Berlin – Charité Vivantes GmbH , Berlin , Germany

3. Labor Berlin – Charité Vivantes GmbH , Berlin , Germany , Phone: +49-30-450 525 308, Fax: +49-30-450 525 901

Abstract

Abstract Background Lactate dehydrogenase (LD) activity is routinely monitored for therapeutic risk stratification of malignant diseases, but is also prone to preanalytical influences. Methods We systematically analyzed the impact of defined preanalytical conditions on the hemolysis-susceptible parameters LD, potassium (K) and hemolysis index in vacuum blood collection tubes (serum [SE], heparin plasma [HP]). Blood was collected by venipuncture from healthy volunteers. Tubes were either filled or underfilled to approximately 50%, then processed directly or stored at room temperature for 4 h. Potassium (K), sodium (Na), chloride (Cl), LD, creatine kinase (CK), total cholesterol, and indices for hemolysis, icterus, and lipemia were analyzed. Filling velocity was determined in a subset of tubes. Findings in healthy volunteers were reconfirmed in an in-patient cohort (n = 74,751) that was analyzed for plasma yield and LD data distribution. Results LD activity was higher in HP compared to SE. Underfilling led to higher LD values (SE: +21.6%; HP: +28.3%), K (SE: +4.2%; HP: +5.3%), and hemolysis index (SE: +260.8%; HP: +210.0%), while other analytes remained largely unchanged. Filling velocity of tubes was approximately 3-fold higher in the first half compared to the second half in both HP and SE collection tubes. Importantly, plasma yield also inversely correlated with LD in routine patients. By calculating reference limits, the lowest plasma yield quartile of the patient cohort displayed LD values clearly exceeding current reference recommendations. Conclusions Underfilling of tubes leads to a higher proportion of blood aspirated with high velocity and relevant elevations in LD. This finding should be considered in cases of clinically implausible elevated LD activities.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Preanalytical Impact of Incomplete K2EDTA Blood Tube Filling in Molecular Biology Testing;Diagnostics;2024-09-02

2. Underfilled blood collection tubes as pathologizing factor for measured laboratory parameters in older patients;Journal of the American Geriatrics Society;2024-02-05

3. In vitro stability of hormones in cow blood samples;Zbornik radova 26. medunarodni kongres Mediteranske federacije za zdravlje i produkciju preživara - FeMeSPRum - zbornik radova;2024

4. Rapid serum tubes reduce transport hemolysis and false positive rates for high-sensitivity troponin T;Clinica Chimica Acta;2023-11

5. Blood Serum Stability Limit and Maximum Storage Time of Bovine Samples;Acta Scientiae Veterinariae;2021-01-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3