Blood Serum Stability Limit and Maximum Storage Time of Bovine Samples

Author:

Kovačević Danijel,Cincović Marko,Belić Branislava,Đoković Radojica,Majkić Mira

Abstract

Background: Measuring metabolic parameters in the blood has been an indispensable tool for assessing the productive and health status of dairy cows for more than 100 years. The values of laboratory parameters depend on various preanalytical, analytical and postanalytical factors. The most important preanalytical factors are sample transport time and temperature, hemolysis, anticoagulant type, and sample volume.Preanalytical factors can lead to reduced stability of the analyte in the sample, which changes their concentration. Loss of stability changes the time of storage and manipulation of the sample, which determines the criteria for its acceptance or rejection. The two stability indicators are stability limit and maximum permissible instability. A stability limit (SL) is defined as the period of time in which a property variation does not exceed a maximum permissible instability (MPI). The aim of this study was to determine the SL and MPI for each analyte in the blood serum of cows and to determine whether SL differs in the function of the presence of preanalytical errors in the blood sample.Materials, Methods & Results: Three hundred samples of dairy cow origin in different periods of lactation participated in this research. They were classified into 6 groups of 50 samples: according to the time from sampling to processing in the laboratory (0-4 h, 4-8 h and over 8 h; all transported on dry ice, protected from environmental factors, without preanalytical errors) and according to the presence of preanalytical errors (group with hemolysis, a group transported at ambient temperature and a group with a small sample volume). Each sample was aliquoted in two portions. One portion was left at +4°C and tested once a day for 6 days of sample storage, and the second portion, placed at -20 °C, was tested once a month for 6 months. The MPI had a value ranging from 1.55 to 8.4. Metabolic profile analytes with lower MPI values (1.51-3.22) were albumin (ALB), total protein (TPROT), UREA, glucose (GLU), calcium (Ca), and phosphorus (P). Higher MPI values (5.1-8.3) were found for nonesterified fatty acids (NEFA), beta-hydroxybutirate (BHB), cholesterol (CHOL), triglycerides (TGC), total bilirubin (TBIL) and aspartat aminotransferase (AST). For most parameters, we can conclude that their PD% changed faster in storage conditions at +4 °C compared to the regime of -20 °C. The largest number of biochemical analytes in bovine blood serum shows preserved stability in the first 6 days at +4°C or 6 months at -20°C if transported to the laboratory within 8 h after sampling in ideal conditions and without the action of preanalytical errors. Prolonged transport under ideal conditions or the existence of preanalytical errors such as transport at room temperature, hemolysis or small sample volume shorten the stability of the ALB, NEFA, GLU, UREA and P. Concentration of all analytesdecreasesduring the stability test except for UREA, NEFA, BHB and for CHOL and TGC in some groups. Variations in parameters such as BHB, NEFA, TBIL, AST, and Ca have shown potential clinical significance. At storage conditions at +4°C, clinically significant variations at at least one measurement point were found for AST (7.5% of samples), BHB (6.1% of samples), NEFA (9.9% of samples) and for TBIL (in 7% of samples).Discussion: This study can help define acceptable delay times and storage conditions for bovine blood samples, which is of great importance because in working with farm animals it is often not possible to take samples in a short time and deliver them to the laboratory, and samples are often burdened with certain preanalytical errors with limited possibilities of re-sampling.

Publisher

Universidade Federal do Rio Grande do Sul

Subject

General Veterinary

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Analytical and Clinical Interference of Sample Hemolysis in Evaluating Blood Biochemical and Endocrine Parameters in Cows;Animals;2024-06-12

2. Pre‐analytical stability of selected biochemical analytes in serum of horses and oxen stored at −20°C;Veterinary Medicine and Science;2024-02-15

3. "Delta check" values and its clinic and laboratory use;Zbornik radova 26. medunarodni kongres Mediteranske federacije za zdravlje i produkciju preživara - FeMeSPRum - zbornik radova;2024

4. In vitro stability of hormones in cow blood samples;Zbornik radova 26. medunarodni kongres Mediteranske federacije za zdravlje i produkciju preživara - FeMeSPRum - zbornik radova;2024

5. Evaluation of Freestyle Optium Neo H and TaiDoc‐TD4235 point‐of‐care meters for measuring blood β‐hydroxybutyrate concentration in sheep;Veterinary Clinical Pathology;2023-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3