A design for external quality assessment for the analysis of thiopurine drugs: pitfalls and opportunities

Author:

Robijns Karen12345,van Luin Matthijs67,Jansen Rob T.P.8,Neef Cees469,Touw Daan J.61011

Affiliation:

1. Dutch Foundation for Quality Assessment in Medical Laboratories (SKML), Section Therapeutic Drug Monitoring and Clinical Toxicology (KKGT), PO Box 43100, NL 2504 AC , The Hague , The Netherlands

2. Central Hospital Pharmacy , The Hague , The Netherlands

3. Haga Teaching Hospital , The Hague , The Netherlands

4. CAPHRI School for Public Health and Primary Care, Maastricht University , Maastricht , The Netherlands

5. Department of Clinical Pharmacy and Toxicology , Maastricht University Medical Centre+ , Maastricht , The Netherlands , Phone: +31-70-3217217, Fax: +31-70-3080140

6. Dutch Foundation for Quality Assessment in Medical Laboratories (SKML), Section Therapeutic Drug Monitoring and Clinical Toxicology (KKGT) , The Hague , The Netherlands

7. Department of Clinical Pharmacy , Rijnstate Hospital , Arnhem , The Netherlands

8. Dutch Foundation for Quality Assessment in Medical Laboratories (SKML) , Nijmegen , The Netherlands

9. Department of Clinical Pharmacy and Toxicology , Maastricht University Medical Centre+ , Maastricht , The Netherlands

10. University of Groningen, University Medical Center Groningen , Department of Clinical Pharmacy and Pharmacology , Groningen , The Netherlands

11. University of Groningen, Groningen Research Institute of Pharmacy , Department of Pharmacokinetics Toxicology and Targeting , Groningen , The Netherlands

Abstract

Abstract Background For the analysis of 6-thioguanine nucleotides (6-TGN) and 6-methylmercaptopurine ribonucleotides (6-MMPR), no external quality assessment scheme (EQAS) is currently available and no quality control samples can be made because of the absence of pure substances. An experimental design is tested to compare laboratory analytical results. Methods In this EQAS, participating laboratories were asked to select patient samples from their routine analysis and exchange these with a coupled laboratory. Because of large differences in results between laboratories, all standard operating procedures were reviewed, revealing that the origin of these differences could be in the method of hydrolysis and the preparation of calibrators. To investigate the contribution of the calibrators to these differences, one participating laboratory was asked to prepare a batch of calibrators to be shipped to the participating laboratories for analysis. Results Results for 6-TGN differed more between laboratories, compared with results for 6-MMPR. For 6-TGN and 6-MMPR 43% and 24% of the results, respectively, were out of the 80%–120% range. When correcting the results from the exchange of the patient samples with the results of the calibrators, the mean absolute difference for 6-TGN improved from 24.8% to 16.3% (p<0.001), while the results for 6-MMPR worsened from 17.3% to 20.0% (p=0.020). Conclusions This first EQAS for thiopurine drugs shows that there is a difference between laboratories in the analysis of 6-TGN, and to a lesser extent in the analysis of 6-MMPR. This difference for 6-TGN can partially be explained by the use of in-house-prepared calibrators that differ among the participants.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3