Analysis of serous body fluids using the CELL-DYN Sapphire hematology analyzer

Author:

Keuren Jeffrey F.W.1,Hoffmann Johannes J.M.L.2,Leers Mathie P.G.1

Affiliation:

1. Department of Clinical Chemistry and Hematology, Atrium Medical Center, Heerlen, the Netherlands

2. Abbott Diagnostics Division , Wiesbaden-Delkenheim , Germany

Abstract

Abstract Background: Correct cell enumeration and differential analysis of body fluids are important in the diagnosis and management of several diseases. Currently, microscopic analysis is still considered the “gold standard”. The aim of the present study was to evaluate the analytical performance of the CELL-DYN Sapphire hematology analyzer for automated differentiation of cells in serous fluids and to explore whether manual analysis of the raw data files could improve the differential count compared with reference microscopy. Methods: A total of 105 serous fluids (39 peritoneal and 66 pleural effusions) were analyzed by the CELL-DYN Sapphire using standard whole-blood algorithm. Additionally, we performed optimized manual gating of the Sapphire raw data file using standard flow cytometry software. Results: The standard Sapphire algorithm showed substantial deviations from the reference microscopic differentiation: polymorphonuclear cell counts were too high because they contained some monocytic cells. However, when optimized manual gating strategy is used, a good correlation and negligible bias were found. Conclusions: We have demonstrated that with a modified algorithm, CELL-DYN Sapphire will provide reliable identification and enumeration of blood cells in peritoneal and pleural fluids

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Recent advances in laboratory hematology reflected by a decade of CCLM publications;Clinical Chemistry and Laboratory Medicine (CCLM);2022-10-27

2. Cell counting chamber vs. Sysmex XN-1000 for determining white blood cell count and differentiation for body fluids;Turkish Journal of Biochemistry;2022-09-19

3. Performance of Abbott Alinity hq hematology analyzer for automated cell counting of body fluids;International Journal of Laboratory Hematology;2021-09-28

4. Automated cell count in body fluids: a review;Advances in Laboratory Medicine / Avances en Medicina de Laboratorio;2021-03-15

5. El recuento automatizado de células en líquidos biológicos: una revisión;Advances in Laboratory Medicine / Avances en Medicina de Laboratorio;2021-02-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3